R PURIFICADOR DE AIRE MANUAL DE INSTALACIÓN MANUAL DE USO PURIFICATORE DELL’ARIA MANUALE D’INSTALLAZIONE MANUALE OPERATIVO Wall-mounting type Wandmontage Type mural De montaje en pared Tipo da montare sul muro Wandmodel *Plasmacluster is a trademark of Sharp Corporation.
ENGLISH An air purifier draws in room air from its air intake, lets the air pass through an Active Carbon Filter (Deodorizing Filter) and a HEPA Filter (dust collection filter) inside of the unit, then discharges the air from its air outlet. The air purifier unit repeats this process by moving its internal fan. As air passes through, the HEPA Filter can remove dust particles. The Active Carbon Filter gradually absorbs odour elements as they repeatedly pass through the filter.
IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, basic safety precautions should be followed, including the following: WARNING - To reduce the risk of electrical shock, fire or injury to persons: • Read all instructions before using the air purifier. • Use only a 220-240 volt outlet . • Do not use the air purifier if the power cord or plug is damaged or the connection to the wall outlet is loose. • Periodically remove dust from the power plug.
REMOTE CONTROL LIMITATIONS DO NOT USE THE REMOTE CONTROL IN THE FOLLOWING LOCATIONS: • Any location where there is inverter lighting equipment or electronic spontaneous lighting equipment The remote control may become inoperative. In this case, move away from such lighting equipment or change direction. • Location exposed to direct sunlight or fluorescent. The unit may not receive signals from the remote control. • Avoid a location where the sensor is exposed to direct wind.
PART NAMES MAIN UNIT DISPLAY Plasmacluster Indicator Light Power ON/OFF button Fan Speed Indicator Lights Fan Control button OFF Timer Display Indicator Lights OFF Timer button Remote Control Receiver Odour Sensor Filter Frame HEPA Filter (white) (with Microbial Control Filter)(blue) Active Carbon Filter (Deodorizing Filter) Stainless Steel Pre-Filter Front Panel ACCESSORIES Remote Control (1 unit) BACK Battery (R6(AA) battery X 2 ) Air Outlet Operation Manual Wall mounting kit • Wall mounting br
PREPARATION INSERTING BATTERIES IN THE REMOTE CONTROL 1 Remove the back cover Press and slide the back cover to remove. Insert batteries with below. − + + − and as shown 3 Close the back cover About the batteries • The battery life is about 1 year. • Replace the batteries when the remote control becomes inoperative. • Incorrect usage of the batteries may cause battery fluid leakage and/or damage.
INSTALLATION FOR APPROPRIATE INSTALLATION To remove room odour Installing the unit high up on the wall is most effective. To remove room dust Comparatively large dust particles such as pollen and house dust collect in the lower strata of the room air. Select a location in the room where the air circulation is good. This improves the cleaning performance and causes Plasmacluster ions to spread throughout the room. Operating Conditions Please operate the unit under the following conditions.
2 Mount wall mounting bracket • Mount the bracket using the included wood screws so that it is maintained level. Installation on a concrete, block or mortar surface Drill holes of at least 35 mm depth and 5 mm diameter into the wall, drive in Fisher plugs, and fix the unit with wood screws. φ 5 mm 3 5 mm Fisher plug Wood screw Installation on a wooden pillar, crosspiece or other wooden surface Use wood screws for installation.
INSTALLATION Before starting the wall installation, be sure to remove the front panel and filter frame. 3 Install the unit on the wall. 1 Filter Frame Front Panel 2 Place the unit facing up, remove the Front Panel and Filter Frame. Air Outlet 1 2 Adjust the length of the power cord. 1 Measure the distance between the unit and the wall outlet. (Refer to E-6) 2 Place the unit face down, and insert the power cord into the power cord adjusting guide so as to adjust it to the measured length.
Apply a mark (tape, etc.) 8 cm above both ends of the wall mounting 3 bracket. Lift up the unit so that the hooking holes on the unit are aligned with 4 the marks, hook the unit onto the wall mounting bracket and slide it to the right. When positioned correctly, the unit will move down slightly until it engages.
FILTER INSTALLATION 1 Be sure to remove the filters from the plastic bags before using the unit. How to Remove the Stainless Steel Pre-Filter Remove the Pre-Filter, Active Carbon Filter and HEPA Filter from the Filter Frame. Tabs Pre-Filter Active Carbon Filter HEPA Filter 2 Remove the Active Carbon Filter and HEPA Filter from the plastic bags. Filter Frame Active Carbon Filter HEPA Filter the HEPA Filter 3 Place within the Filter Frame.
Filter Frame ENGLISH Mount the Filter Frame to 6 the main unit. in the usage start date 7 Fill on the Date Label. Use the date as a guide for the Filter Replacement schedule. Date Label Claw the Front Panel to 8 Mount the main unit. Claw socket Front Panel the power plug into 9 Insert the wall outlet and check on/off operation using the remote control.
OPERATION For the first 30 seconds after the plug is inserted into the wall outlet, the unit will check the conditions of the air. • Auto Operation Odour sensor checks the amount of impurities in the air and the fan speed switches automatically. • Manual Operation Regardless of the amount of impurities, desired fan speed can be switched between Silent and Max. MAIN UNIT OPERATION POWER ON/OFF button • Used to start AUTO operation (short beep) and stop operation (long beep).
Plasmacluster Ion Operation While the product is in operation, the unit will constantly discharge approximately the same amount of Positive and Negative cluster ions. This is effective for reducing some airborne mold. POWER ON/OFF button • Used to start AUTO operation (short beep) and stop operation (long beep). • Plasmacluster Indicator Light, and Fan Speed Indicator Light (AUTO) turn on/off. • Unless unplug the power cord, the operation starts in the previous mode the unit was operated in.
CARE AND MAINTENANCE To maintain optimum performance of this air purifier, please clean the unit including the sensor and filters periodically. When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result. FILTER REPLACEMENT GUIDELINES Depending on the usage environment, air outlet odour may become strong after several months. If dust or odours cannot be removed easily, replace the filters.
MAIN UNIT To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to remain, they may become hard to clean. Wipe with a dry, soft cloth For stubborn stains or dirt, use a soft cloth dampened with warm water. Do not use volatile fluids Benzene, paint thinner, polishing powder, etc., may damage the surface. Do not use detergents Detergent ingredients may damage the unit.
TROUBLESHOOTING Before calling for repair, please review the list below, since the problem may not be a unit malfunction. SYMPTOM REMEDY (not a malfunction) The Remote Control does not work • Have the batteries been depleted? • Are the batteries inserted correctly? • Is a fluorescent lighting in the room flickering due to service life? (Refer to E-5,E-9) Odours and smoke are not removed • Replace the filters if they appear to be heavily soiled.
ENGLISH
SHARP CORPORATION Printed in Japan TINS-A119KKRZ 04BK 1