Service manual

FO-IS125N
2 – 18
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Initial
setting
Remarks
10
SW
36
1Reserved 0
2Reserved 0
3Reserved 0
4Reserved 0
5Reserved 0
6Reserved 0
7Reserved 0
8Reserved 0
SW
37
1
2
Delay timer before line connect in
auto dial
0sec 1.5sec 3.0sec
0
0
No. 1 0 0 1
No. 2 0 1 0
3
4
Delay timer after line connect in auto
dial
1.7sec 3.0sec 3.6sec 4.0sec
0
0
No. 30011
No. 40101
5
6
Calling time 45sec 90sec 55sec
0
0
No. 5 0 0 1
No. 6 0 1 0
7
8
CNG timing 3.5sec 1.5sec 3.0sec
0
0
No. 7 0 0 1
No. 8 0 1 0
SW
38
1 Dial tone detection (before auto dial) On Off 0 OPTION
2 Busy tone detection (after auto dial) On Off 1
3 Recall control (for FCC Part68) On Off 1
4Reserved 0
5Reserved 0
6Reserved 0
7Reserved 0
8Reserved 0
SW
39
1Reserved 0
2Reserved 0
3Reserved 0
4Reserved 0
5Reserved 0
6Reserved 0
7Reserved 0
8Reserved 0
SW
40
1Reserved 0
2Reserved 0
3Reserved
0
4Reserved 0
5Reserved 1
6Reserved 1
7
8
Paper Size LETTER A4 LEGAL LETTER
0
0
OPTION
LETTER/
LEGAL only
No. 70011
No. 80101
SW
41
1Reserved 0
2 Dial pause 4sec 2sec 0
3
4
Line density selection STAN-
DARD
FINE S-FINE STAN-
DARD
0
0
OPTION
FINE/STAN-
DARD only
No. 30011
No. 40101
5 Activity report print Yes (When memory full) No (First data is cleared when
memory full)
0OPTION
6 Daylight saving No Yes 1 OPTION
7 Print setting of received fax for Fax
to e-mail
Print at error Always print 0 Fax to e-mail/
Folder
8Reserved 0