Service manual

FO-DC600U
1 Reserved 1
2 V.34 mode function On Off 1
3 V.34 control channel communication speed 2400bps 1200bps 0
EOL detection timer 13sec 25sec 5sec 5sec
4 No. 4 0 0 1 1 0
SW34
5 No. 5 0 1 0 1 0
Processing of DIS reception after DIS
Command
A line is Apply to T.30+α
transmission
retransmitting
cut T.30
6 No. 6 0 0 1 1 0
7 No. 7 0 1 0 1 0
8 Reserved 0
DTMF output level (High) Binary input 16 8 4 2 1
For For
No. = 1 2 3 4 5 (Data No.) n x 0.5dBm
U.S.A. Canada
1 EX 0 1 1 0 0 (For U.S.A.) 0 0
2 EX 0 1 0 0 0 (For Canada) 1 1
3 eg. Signal transmission level is set to -10dBm 1 0
SW35
4 00
5 00
6 Reserved 0
7 Reserved 0
8 Reserved 0
DTMF output level (Low) Binary input 16 8 4 2 1
For For
No. = 1 2 3 4 5 (Data No.) n x 0.5dBm
U.S.A. Canada
1 EX 1 0 0 0 0 (For U.S.A.) 1 0
2 EX 0 1 1 0 0 (For Canada) 0 1
3 eg. Signal transmission level is set to -10dBm 0 1
SW36
4 00
5 00
6 Reserved 0
7 Reserved 0
8 Reserved 0
1 Reserved 0
2 Reserved 0
3 Reserved 0
SW37
4 Reserved 0
5 Reserved 0
6 Reserved 1
7 Reserved 0
8 Reserved 1
1 Reserved 0
2 Reserved 0
3 Reserved 0
4 Reserved 0
SW38
Distinctive ringing OFF STD RING1 RING2 RING3 RING4 RING5
5 No. 5 0 0 1 0 1 0 1 0
6 No. 6 0 0 0 1 1 0 0 0
7 No. 7 0 0 0 0 0 1 1 0
8 No. 8 0 1 0 0 0 0 0 0
1 Reserved 0
2 Reserved 0
3 Reserved 0
SW39
4 Reserved 0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 1
2 16
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Remarks
Initial
setting
10