Service manual

FO-90AAR
1 Busy tone continuous sound detect time 5sec 10sec 1
2 Busy tone detect continuation sound detect No Yes 0
during OGM
3 Busy tone detect continuation sound detect No Yes 0
4 Busy tone detect intermittent sound detect No Yes 0
during OGM
5 Busy tone detect intermittent sound detect No Yes 0
Busy tone detection pulse number 2pulses 4pulses 6pulses 10pulses
6 No. 6 0 0 1 1 0
7 No. 7 0 1 0 1 1
8 Reserved 0
Busy tone detection ON/OFF time 150ms 200ms 250ms 350ms
1 (Lower duration) No. 1 0 0 1 1 0
2 No. 2 0 1 0 1 1
Busy tone detection ON/OFF time 650ms 900ms 1500ms 2700ms
3 (Upper duration) No. 3 0 0 1 1 0
4 No. 4 0 1 0 1 1
5
Busy tone continuation sound detect frequency
320Hz-570Hz 320Hz-460Hz 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
ICM recording time 4min 15s 30s 60s OPTION
1 No. 1 0 0 1 1 0
2 No. 2 0 1 0 1 0
A.M. Quiet time 1 2s 3s 4s 5s
3 No. 3 0 0 1 1 0
4 No. 4 0 1 0 1 0
A.M. Quiet time 2 0s 1s 2s 3s
5 No. 5 0 0 1 1 1
6 No. 6 0 1 0 1 0
7 Key input buzzer on/off switch On Off 0
(Two way recording mode)
8 Reserved 0
A.M. Quiet detect time Binary input
1 No. = 16 8 4 2 1 0
2 1 2 3 4 5 0
3 0 0 1 1 0 1
4 1
5 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
1 Reserved 0
2 Max OGM record time 15s 60s 0
3 2way record function Disable Enable 0
4 Toll saver Disable Enable 0 OPTION
5 FAX reception in case of detecting No sound Yes No 1
detect after ICM recording
6 Reserved 0
7 Reserved 0
8 Transfer dial recall Disable Enable 0
SW
l
H1
SW
l
H2
SW
NO.
DATA
NO.
ITEM
Switch setting and function
1
0
2 – 10
Remarks
Initial
setting
SW
l
I1
SW
l
I2
SW
l
I3