Service manual

UX-68DE
FO-78DE
5. Externally connected TEL OFF HOOK detection circuit section
The circuit current detection is turned on together with OFF HOOK
of main body or OFF HOOK of externally connected TEL. ON of
CML OFF (HS=L) is judged as OFF HOOK of externally connected
TEL.
6. CI detection circuit
CI is detected by the photocoupler which is integrated in series in
the primary side TEL circuit well proven in the existing unit.
5 – 10
Signal Name Description
CML Line connecting relay
(The circuit is located H: Line make
in the TEL/LIU PWB.) L: Line break
SP MUTE Speaker tone mute control signal
(The circuit is located H: Muting (Power down mode)
in the TEL/LIU PWB.) L: Muting cancel (Normal operation)
Handset reception mute control signal
TEL MUTE H: Muting
L: Muting cancel
DPON Connecting DC circuit and DP generating
(The circuit is located
H: Line connect / Make
in the TEL/LIU PWB.) L: Line disconnect / Break
DPMUTE
Adjust the resistance
during make ratio
(The circuit is located
H: Muting
in the TEL/LIU PWB.) L: Muting cancel
TXMUTE Tx route mute circuit
(The circuit is located
H: Muting
in the control PWB.)
L: Muting cancel
4) Signal selection
The following signals are used to control the transmission line of TEL/
FAX signal. For details, refer to the signal selector matrix table.
[Control signals from output port]
VOL A VOL B VOL C
ON-HOOK ICM/OGM ICM/OGM
OUTPUT VALUE (GP02) (GP03) (GP04) Receiving MONITOR PLAY RINGER BUZZER DTMF/DP
X 0 1K 0 0 0 HIGH HIGH
X 1 10K 1 0 0 HIGH HIGH MIDDLE1
X 2 39K 0 1 0 MID 1 MID 1 MIDDLE2
X 3 100K 1 1 0 MID 2 MID 2 MIDDLE3
X 4 200K 0 0 1 MID 3 MID 3 LOW MIDDLE
X 5 300K 1 0 1 FIXED
X 6 470K 0 1 1 LOW LOW FIXED
X 7 750K 1 1 1 LOW
VOLUME SETTING