Rapid key 11: Life entry mode
(For Serviceman temporary counter)
The mode is used to set a desired value for the judgment value (alarm
judgment counter value) of the general purpose life counters 1 through
3 of the printer. If the life of a consumable part (developer, imprinter, etc)
is set, the model which has the error display and RMS function will in-
form RMS when the counter reaches the set value. For setting, proceed
with the following procedure.
When the life counter setting mode is selected, the following will be
displayed.
The cursor blinks at the top data.
Three counters can be selected with the "#" and " " keys.
In the state , input a desired setting number of 6 digits with the
ten-key.
After input of 6 digits, shift to another counter with the "#" and " "
keys as necessary. When all necessary counters are completely in-
put, press the START key.
"STORED" will be displayed with the set values stored into the
memory. For checking, retry this mode.
NOTE: The counter shows the operational state of the printer (how many
sheets have been printed since start of use?). The ordinary
memory does not reset the counter. Accordingly, it is necessary
to reset this counter in addition to the ordinary memory clear if
the content in the memory on the control PWB is broken be-
cause of PWB repair, etc. (In the production stage, it is neces-
sary to execute this in the last process.)
LI FE1= 0000
LI FE2= 0000
LI FE3= 0000
0
0
0
# key
key
0
0
0
Rapid key 12: Life clear mode
The mode is used to respectively clear the life counter of the printer and
the counter of the auto feeder. For setting, proceed with the following
procedure.
When the life counter clearing mode is selected, the following will be
is displayed.
MACH I NE
DRUM
L
LIFE
LIFE
IFE1
LEAR
FEEDER L I FE LEAR
TONER L I FE LEAR
LEAR
LEAR
LIFE2
LEAR
LIFE3
LEAR
C
C
C
C
C
C
C
key
# key
Seven counters can be selected with the "#" and " " keys.
In the state , input the DEL key, and the counter will be respectively
cleared.
CLEARED is displayed and clearing is complete. After ending one
clear, move to another counter to clear with the # key, key, if
necessary. After clearing the necessary counter press down the
STOP key.
NOTE: The counter shows the operational state of the printer (how many
sheets have been printed since start of use?). The ordinary
memory does not reset the counter. Accordingly, it is necessary
to reset this counter in addition to the ordinary memory clear if
the content in the memory on the control PWB is broken be-
cause of PWB repair, etc. (In the production stage, it is neces-
sary to execute this in the last process.)