Service manual
UX-B700U
FO-B1600U
2 – 8
1 Protect from echo No Yes 0
2 Forced 4800bps reception Yes No 0
3 Footer print Yes No 0
4 Length limitation of copy/send/receive No limit Copy/Send: 60 cm 0
Receive: 1 m
5 CSI transmission Not transmitted Transmitted 0
6 DIS receive acknowledgement during G3 Twice NSF: Once 0
transmission DIS: Twice
7 Non-modulated carrier for V29 transmission Yes No 0
mode
8 EOL (End Of Line) detect timer 25 s 13 s 0
Modem speed V.33 V.17 V.29 V.27 ter
14400 12000 14400 12000 9600 7200 9600 7200 4800 2400
1 0011110000 1
2 1100000000 0
3 0101010110 0
4 0000111100 0
5 Sender’s information transmit No Yes 0
6 Reserved 0
7 Communication error treatment in RTN No communication error Communication error 0
sending mode (Reception)
8 CNG transmission No Yes 0
CED tone signal interval 1000ms 750ms 500ms 75ms
1 No. 1 1 1 0 0 0
2 No. 2 1 0 1 0 0
3 MR coding No Yes 0
4 ECM mode No Yes 0 OPTION
5 ECM MMR mode No Yes 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
1 Signal transmission level Binary input 0
2 No. = 16 8 4 2 1 1
3 1 2 3 4 5 0
4 EX 0 1 0 0 0 0
5 eg. Signal transmission level is set to –8dBm. 0
6 Protocol monitor (Error print)
Printed at communication error
Not printed 0
7 Protocol monitor Yes No 0
8 Line monitor Yes No 0
8. Soft switch description
• Soft switch
SW
NO.
DATA
NO.
ITEM
Switch setting and function
1
0
Remarks
Initial
setting
SW
l
A1
SW
l
A2
SW
l
A3
SW
l
A4
2 – 8