Service manual
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Initial
setting
Remarks
10
SW
l
H1
1 Busy tone detection ON/OFF time (Lower
duration)
350ms 200ms 0
2 Busy tone detection ON/OFF time (Upper
duration)
650ms 900ms 0
3 Reserved 0
4 Busy tone continuous sound detect time 5s 10s 1
5 Reserved 0
6 Busy tone detect continuation sound detect
(during ICM: for internal A.M.)
No Yes 0
7 Reserved 0
8 Busy tone detect intermittent sound detect
(during ICM: for internal A.M.)
No Yes 0
SW
l
H2
Busy tone detection pulse number 2pulses 4pulses 6pulses 10pulses
1 No. 1 0 0 1 1 0
2 No. 2 0 1 0 1 1
3 Fax switching when A.M. full Yes No 0 OPTION
4 Reserved 0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
SW
l
I1
1 Reserved 0
2 Reserved 0
3 Reserved 0
4 Reserved 0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
SW
l
I2
1 Reserved 0
2 Reserved 0
3 Reserved 0
4 Reserved 0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
SW
l
I3
1 Reserved 0
2 Reserved 0
3 Reserved 0
4 Reserved 0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
SW
l
I4
1 Reserved 0
2 Reserved 0
3 Reserved 0
4 Reserved 0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
UX-510U/UX-510C/UX-500U
UX-500C/FO-1460U
2 – 9