34
E
SCREEN menu
Function
Command Direction
Parameter Reply Control/Response contents *1
*2
(A) (B)
AUTO ASNC W 1 When the input mode is PC D-SUB, PC RGB.
-
○ ○
CLOCK CLCK WR 0-1200 0-1200 When the input mode is PC D-SUB, PC RGB. 
Varies depending on the signal.
PHASE PHSE WR 0-63 0-63 When the input mode is PC D-SUB, PC RGB.
POSITIONING POSITION OF 
THE LONGEST 
DIRECTION
HPOS WR 0-100 0-100 0-800 on PC D-SUB, PC RGB.
Varies depending on the signal.
POSITION OF 
THE SHORTEST 
DIRECTION
VPOS WR 0-100 0-100 0-200 on PC D-SUB, PC RGB.
Varies depending on the signal.
SIZE SIZE OF THE 
LONGEST 
DIRECTION
HSIZ WR 0-100 0-100
SIZE OF THE 
SHORTEST 
DIRECTION
VSIZ WR 0-100 0-100
RESOLUTION
LONGEST 
DIRECTION 
RESOLUTION
HRES WR 300-1920 300-1920 When the input mode is PC D-SUB, PC RGB. 
Only even numbers are valid for parameters. 
Varies depending on the signal.
SHORTEST 
DIRECTION 
RESOLUTION
VRES WR 200-1200 200-1200
RESET ARST W 1