Main comsents
Manufacturer Model Name Quantity
SMC Corporation AF3000-02C Air filter 1
SMC Corporation AFM3000-02C Mist separator 1
SMC Corporation AR3000-02G-1 Regulator with 200 kPa pressure gauge 1
SMC Corporation Y30L Spacer assembly with L-type bracket 2
SMC Corporation KQ2S06-M5 Air nipple 1
Note
The air filter and mist separator should incorporate a float-type auto drain (NC) mechanism.
Use a drain tube with a diameter of at least 4 mm and length of 5 m or less. Set the tubes so that there is no
rising.
Tube Layout Notes
Tube arrangement
Use tubes with a bending radius of at least 15 mm and make sure that there are no sharp bends. Also, if the
tubes are laid parallel within the ducts for the electrical wiring or hydraulic tubes, be careful that the tubes
are not crushed by the movement of the ducts.
Tube length
To inject air simultaneously into multiple scales, make the tubes the same length from the distributor of the
air supply unit to each scale so that the injection air pressure is uniform for each scale.
Pressure setting and tube length for pressure reducing valve
If the air injection pressure for each scale is around 20 ±10 kPa, the air in the scale can be maintained at a low
humidity. However, setting the air injection pressure only via the pressure reducing valve will not result in an
air injection pressure of 20 ±10 kPa due to pressure losses stemming from the tube length.
Refer to graph below to determine the pressure setting of the pressure reducing valve.
Pressure reduction setting and tube length
Length of polyurethane tube with outer diameter of 6 mm and inner diameter of 4 mm
(kPa)
(m)
Pressure setting of pressure reducing valve
0
0
5
10
15
20
25
30
35
40
12345678910
Fig. 4-2
This graph illustrates the relationship between the regulator pressure setting and tube length when the air
injection pressure is 20 kPa. The tube length here is considered to be the length from the distributor of the air
supply unit to the scale. When the air injection pressure is 20 kPa, the air consumption amount per scale unit
is approximately 30 N /min.