Specifications
14
Table 1 : Panel voltage setting table :
Input voltage via
PP2/PP3, PP5 Panel Voltage JA3 JA5
JA6 Jumper on board
12VDC
3.3V 3V3 closed 1-3 & 2-4 1-3 & 2-4
5V 5V closed 1-3 & 2-4 1-3 & 2-4
12V OPEN 1-3 & 2-4 5-7 & 6-8
CAUTION: Incorrect setting can damage panel & controller
Input voltage via
PP2/PP3, PP5 Panel Voltage JA3
JA5 JA6 Jumper on board
24VDC**
3.3V 3V3 closed 1-3 & 2-4 1-3 & 2-4
5V 5V closed 1-3 & 2-4 1-3 & 2-4
12V 12V closed 1-3 & 2-4 3-5 & 4-6
18V
18V closed 1-3 & 2-4 3-5 & 4-6
CAUTION: Incorrect setting can damage panel & controller
** Ensure that the backlight inverter supports 24V operation prior to connecting a 24VDC
input. Because CNA1 pin 1 and CNB1 pin 2 will output 24VDC if input 24VDC via PP2/PP3 or
PP5.