Specifications

Main code Sub code Content
26 43 Side void setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of the side void amount is displayed.
2. Enter the code number and press the start key. The setting is changed.
44 SPF document rear edge read setup + Fax document rear edge scan setup.
When this simulation is executed, the currently set code number is displayed. Enter the desired code number
and press the START key, and the display will be changed. The document rear edge scanning area in SPF
reduction (less than 100%) copy is changed.
The code number is changeable in the range of 0 8.
The default value is 4, and 2 mm of the document rear edge is cut.
When the value is changed by 1, the area is changed by 1 mm.
30 01 Paper sensor status display
The paper sensor status is displayed with the lamps on the operation panel.
43 01 Fusing temperature setup (Normal copy)
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code number Setting
00 mm
1 0.5 mm
2 1.0 mm
3 1.5 mm
4 2.0 mm *Default
5 2.5 mm
6 3.0 mm
7 3.5 mm
8 4.0 mm
9 4.5 mm
10 5.0 mm
Display Sensor
Developer cartridge replacement lamp Paper detection before resist (PPD1)
JAM lamp Fusing section paper detection (PPD2)
Photoconductor cartridge replacement lamp Paper exit paper detection (POD)
2nd cassette lamp 2nd CS paper detection (PPD3)
Zoom lamp New drum cartridge detection (PUIS)
AE lamp Single manual feed paper detection (MFD)
Exposure level 1 (Light) lamp Main cassette A4 width detection (PSW1)
Exposure level 5 (Dark) lamp 2nd cassette A4 width detection (PSW2)
Code number Set temperature (˚C)
0 175
1 180
2 185
3 190
4 195 ( Default)
5 200
DM-1505