Specifications
Main code Sub code Content
26 38 Cancel of stop at drum life over
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
39 Memory capacity setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
40 Polygon motor OFF time setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
42 Transfer ON timing control setup
(Operation / Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed. (For any number different
from the following ones, the default time is automatically set.)
Code number Setting
0 Stop at drum life over
1 Stop cancel at drum life over
Code number Setting
0 No memory
1 4 Mbyte
2 6 Mbyte
Code number Setting
0 0 sec
1 30 sec
2 60 sec
3 90 sec
Code number Setting
0 Default (330 msec)
1 –40 msec
2 –30 msec
3 –20 msec
4 –10 msec
5 Default (330 msec)
6 +10 msec
7 +20 msec
8 +30 msec
9 +40 msec
DM-1505
9 – 6