Service manual

RCD2200M
8 – 4
For example: In case the exhaust thermistor works incorrectly (275ml water load is necessary), the display will show “no” as follows. In
that case, the exhaust thermistor should be checked or replaced.
5. Set of standard voltage (SF-7)
When the control unit or the relay unit is replaced, set the standard voltage, referring to following procedure. Because the control unit judges if the AC
supply voltage is 230V or 208V by comparing with the standard voltage. The temporary standard voltage is set when the oven is shipped from the fac-
tory. But when the control unit is replaced to new one, it does not have the standard voltage. When the relay unit is replaced to new one, set the stan-
dard voltage too. Because the signal from the relay unit to detect the AC supply voltage has error of ±5%.
The standard voltage can be set by using this function.
For example: Procedure to set the standard voltage (in case input voltage is 230V ±1V)
Image of the standard voltage is as follows;
When the oven detects the AC supply voltage is 230V, the control unit calculates the standard voltage is 219V. Because 230V- 11v = 219V.
When the oven detects the AC voltage is 208V, the control unit calculates that the standard voltage is 219V. Because 208V + 11V = 219v.
NOTE: 11V is not exact.
For example: In case that AC supply voltage is out of range from tentative memorized voltage (standard voltage ±13%), the display will
show “----” as follows.
At that time, the voltage of AC power may be not suitable or the control unit and /or the relay unit may be out of order.
Operation Display Indicator Sound
(within 20 sec.)
(within 20 sec.)
plug in
SELECT POWER
SET MEMORY
START
STOP/CLEAR
6
START
(after 5 min.)
STOP/CLEAR
STOP/CLEAR
ON
.
.
.
.
SF-
SF-6
5.00
(count down)
no
SF-1
0
or
Operation Display Indicator Sound
(within 20 sec.)
(within 20 sec.)
plug in
SELECT POWER
SET MEMORY
START
STOP/CLEAR
7
START
(after 1 sec.)
STOP/CLEAR
.
.
.
.
SF-
230U
230U
SF-
0
(currnt voltage)
Flashing
Operation Display Indicator Sound
(within 20 sec.)
(within 20 sec.)
plug in
SELECT POWER
SET MEMORY
START
STOP/CLEAR
7
START
STOP/CLEAR
.
.
.
.
SF-
----
0