Technical data

Rev.February 1996 Conti-Dryer Page 25
CD 25-600
6.0 MAINTENANCE
6.1 Maintenance of lters
The CD features the following lters:
Designation Type of lter Check-up intervals Check-up procedure
Intake lter (8) Wire mesh As required Check-up and clean using air.
At insuf cient result, wash the
lter.
Recirculation Cartridge As required Check-up and clean using air.
lter (81) (paper) Recommendation: At insuf cient result, replace
50 hours the lter
Filter bag (9) Polyester As required. Check-up and clean using air.
Recommendation: At insuf cient result, replace
50 hours lter.
Return air Wire mesh As required: Check-up and clean using air.
lter (105) Recommendation: At insuf cient result, replace
50 hours replace lter.
R1643