Technical data
Rev.February 1996 Conti-Dryer Page 18
CD 25-600
4.4 Control
4.4.1 Control buttons
(13) Temperature controller
(14) Fuse
(15) Diode - power on
(16) Diode - overtemperature
(17) Diode - motor overloaded
(18) Main switch
On CD 25-180 units the whole control box can
be tilted to an angle of 90 degrees thus providing
easy access to all front components. On CD
350-600 units the control front plate is integrated
in the cabinet. Access to components via side
door in cabinet. R1632
4.4.2 Temperature controller (13)
Temperature adjusting button (19)
Button for adjusting temperature. Temperature scale values displayed in both °C and °F.
°C: Large, white text
°F: Small, green text
Adjusting the drying temperature in the area 80-130° C.
Hysteresis adjusting button (20)
Button for adjusting hysteresis
(temperature fl uctuation area).
The button is placed on side of the temperature controller.
The button for hysteresis adjustment is factory preset
to approx. mid area.
Further adjustments are usually not required.
Diode voltage on (21)
«Power on» indicates that the temperature
controller is connected. R1633
Diode, heater on (22)