Technical data
Rev.February 1996 Conti-Dryer Page 17
CD 25-600
4.2 Disassembly
If it is required to disassemble the Conti-Dryer, all material must be discharged fi rst.
Power must be disconnected, and Con-Evator, if attached, disassembled. The Conti-Dryer
can now be handled in the lifting fi xture (10). See fi g. 4.1.1
4.3 Connections
1. Check that the voltage available correspond to the voltage requirement indicated on
the typeplate. The typeplate is located on side of the control (see point 3.1).
2. Connect the machine according to diagram. To be found in the back of the manual.
3. Turn on the machine using the main switch and check that the blower runs arrow
directed.
If not, switch two phases.
4. If a vacuum conveyor is attached, it can be power supplied from the CD. Terminals
have been set out for this purpose (terminal 7.8.9 and PE).
Check revolving direction at start-up of the vacuum conveyor. A label is attached
on the ventilation cover where the long arrow indicates conveying and the short one
fi lter cleaning. (See also manual for Con-Evator).
5. A potential free contact is available for connection of an external alarm. See diagram
in the pocket in the back of the manual.
6. The control which is usually fi xed on the unit can be placed remotely up to 10 m
from the unit.
7. By remote placing the control must be turned vertically placed, like on the unit.