Electrical installation
For the connection of pin 9 and 10 only use cable with twisted cores, e.g. the SICK
connection cables available as accessories (see chapter 12.7 “Accessories” on
page 111).
If you do not use EFI device communication, to improve the EMC behaviour we
recommend, especially on cascaded systems, the termination of the pin 9 and 10
connections (EFI device communication) on the system connection in the control
cabinet using a resistor of 182 (see section 12.7 “Accessories” on page 111).
6.2 Configuration connection M8× 4 (serial interface)
Pin Sender/ Receiver PC-side RS@232-D@Sub
1 Not assigned
2 RxD Pin 3
3 0 V DC (voltage supply) Pin 5
4 TxD Pin 2
The pin assignment of sender and receiver is identical.
After configuration always remove the connecting cable from the configuration connec-
tion!
After the configuration of the device has been completed, locate the attached
protection cap to cover the configuration connection.
Notes
Fig.
33
:
Pin assignment
configuration connection
M8
× 4
Tab.
16
:
Pin assignment
configuration connection
M8
× 4
Notes
4
2
3