Product description
3.4.2 Status indicators of the receiver
Display Meaning
Orange Cleaning or realignment required
Yellow Reset required (on C4000 Guest has no function)
Red System providing signals for shutting down the machine (switching
output off)
Green System enabled (switching output on)
Bypass active
System error. Disconnect the supply voltage to the C4000 for at least
3 seconds. If the problem persists, replace the unit.
Poor alignment to sender.
Please refer to chapter 7.2 “Aligning sender and receiver” on page 63.
Operation with large protective field width (only after switching on)
Operation with reduced resolution and/or blanking
Non-coded operation (only after switching on)
Operation with code 1 (only after switching on)
Operation with code 2 (only after switching on)
Emergency stop active
Other
displays
All other displays are error messages. Please refer to chapter “Fault
diagnosis” on page 68.
Fig.
8
:
Status indicators of
the receiver
Tab.
3
:
Status indicators of
the receiver
Orange
Yellow
Red
Green
7;segment display