Operating instructions

Chapter 13 Operating Instructions
C4000 Standard/Advanced
116 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8009861/WA65/2012-06-12
Subject to change without notice
Annex
13.2 Checklist for the manufacturer
Checklist for the manufacturer/OEM for the installation of electro-sensitive
protective equipment (ESPE)
The details on the items listed below must be available at the latest when the system is commissioned for the first
time, depending, however, on the various applications the requirements of which must be reviewed by the manufac-
turer/OEM.
This checklist should be retained and kept with the machine documentation to serve as reference during recurring
tests.
1. Have the safety rules and regulations been observed in compliance with the
directives/standards applicable to the machine?
Yes & No &
2. Are the applied directives and standards listed in the declaration of conformity? Yes & No &
3. Does the protective device fulfil the required PL/SILCL and PFHd according to
EN ISO 13849C1/EN 62061 and the type according to EN 61496C1?
Yes & No &
4. Is the access to the hazardous area/hazardous point only possible through the protective field of
the ESPE?
Yes & No &
5. Have appropriate measures been taken to prevent (mechanical point-of-operation guarding)
or monitor unprotected presence in the hazardous area when protecting a hazardous area/
hazardous point and have these been secured against removal?
Yes & No &
6. Are additional mechanical protective measures fitted and secured against manipulation which
prevent reaching below, above or around the ESPE?
Yes & No &
7. Has the maximum shutdown and/or stopping time of the machine been measured, specified
and documented (at the machine and/or in the machine documentation)?
Yes & No &
8. Has the ESPE been mounted such that the required minimum distance from the nearest
hazardous point has been achieved?
Yes & No &
9. Are the ESPE devices properly mounted and secured against manipulation after adjustment? Yes & No &
10. Are the required protective measures against electric shock in effect (protection class)? Yes & No &
11. Is the command device for resetting the protective devices (ESPE) or restarting the machine
present and correctly installed?
Yes & No &
12. Are the outputs of the ESPE (OSSDs, ASCInterface Safety at Work) integrated in compliance with
the required PL/SILCL according to EN ISO 13849/EN 62061 and does the integration comply
with the circuit diagrams?
Yes & No &
13. Has the protective function been checked in compliance with the test notes of this
documentation?
Yes & No &
14. Are the given protective functions effective at every setting of the operating mode selector
switch?
Yes & No &
15. Are the switching elements activated by the ESPE, e.g. contactors, valves, monitored? Yes & No &
16. Is the ESPE effective over the entire period of the dangerous state? Yes & No &
17. Once initiated, will a dangerous state be stopped when switching the ESPE on or off and when
changing the operating mode, or when switching to another protective device?
Yes & No &
18. Has the information label “Important Information” for the daily check been attached so that it is
well visible for the operator?
Yes & No &
This checklist does not replace the initial commissioning, nor the regular inspection by qualified safety personnel.