Service manual

17
R-1405
R-1406
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
Resistance between;
BLU (1) AND YLW (4) = 0 (Shorted)
BLK (2) AND YLW (4) = 60
BLU (1) AND BLK (2) = 60
RED(5) AND BLU (1) = 162
RED(5) AND BLK (2) = 102
YLW(4) AND RED (5) = 162
6-PIN CONNECTOR
OF HOOD FAN MOTOR
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
BLU BLK
YLW RED
1 2
4 5
60
102
HOOD FAN
CAPACITOR
YLW
RED
BLU
BLK
1
2
4
5
SUB
60 Hz
120 v
MAIN