Service manual
AEXM24HR
1 – 3
2. COOLING CAPACITY TABLE
3. HEATING CAPACITY TABLE
[4] ELECTRICAL PARTS
Oper-
ating
Status
Combination of Indoor Units Cooling Capacity (kW)
Running Current
(A)
Power Consumption
(W)
ABCDABCD
RATING (Min.-
Max.)
RATING (Min.-
Max.) RATING (Min.-Max.)
4-
Room
09 09 09 09 1.75 1.75 1.75 1.75 7.0 (3.0-8.2) 10.0 (2.7-13.6) 2180 (600-2980)
12 09 07 07 2.40 1.80 1.40 1.40 7.0 (3.0-8.2) 10.0 (2.7-13.6) 2180 (600-2980)
09 09 09 07 1.85 1.85 1.85 1.44 7.0 (3.0-8.2) 10.0 (2.7-13.6) 2180 (600-2980)
12 07 07 07 2.55 1.48 1.48 1.48 7.0 (3.0-8.2) 10.0 (2.7-13.6) 2180 (600-2980)
09 09 07 07 1.97 1.97 1.53 1.53 7.0 (3.0-8.2) 10.0 (2.7-13.6) 2180 (600-2980)
09 07 07 07 2.10 1.63 1.63 1.63 7.0 (3.0-8.2) 10.0 (2.7-13.6) 2180 (600-2980)
07 07 07 07 1.75 1.75 1.75 1.75 7.0 (3.0-8.2) 10.0 (2.7-13.6) 2180 (600-2980)
3-
Room
09 09 09 OFF 2.27 2.27 2.27 OFF 6.8 (2.7-7.4) 10.1 (2.4-13.3) 2200 (530-2900)
12 09 07 OFF 2.91 2.19 1.70 OFF 6.8 (2.7-7.4) 10.1 (2.4-13.3) 2200 (530-2900)
12 07 07 OFF 3.14 1.83 1.83 OFF 6.8 (2.7-7.4) 10.1 (2.4-13.3) 2200 (530-2900)
09 09 07 OFF 2.45 2.45 1.90 OFF 6.8 (2.7-7.4) 10.1 (2.4-13.3) 2200 (530-2900)
09 07 07 OFF 2.50 1.95 1.95 OFF 6.8 (2.7-7.4) 9.2 (2.4-13.3) 2200 (530-2900)
07 07 07 OFF 1.97 1.97 1.97 OFF 5.9 (2.7-7.3) 8.0 (2.4-12.6) 1750 (530-2760)
2-
Room
12 09 OFF OFF 3.20 2.40 OFF OFF 5.6 (2.0-6.8) 8.3 (2.0-12.4) 1820 (430-2700)
12 07 OFF OFF 3.35 1.95 OFF OFF 5.3 (2.0-6.7) 7.3 (2.0-12.0) 1590 (430-2630)
09 09 OFF OFF 2.50 2.50 OFF OFF 5.0 (2.0-6.3) 6.4 (2.0-11.0) 1400 (430-2400)
09 07 OFF OFF 2.59 2.01 OFF OFF 4.6 (2.6-5.9) 5.6 (2.0-9.2) 1230 (430-2000)
07 07 OFF OFF 2.00 2.00 OFF OFF 4.0 (2.6-5.3) 4.8 (2.0-7.8) 1040 (430-1700)
1-
Room
12 OFF OFF OFF 3.4 OFF OFF OFF 3.4 (1.6-4.0) 4.1 (1.8-6.0) 900 (400-1320)
09 OFF OFF OFF 2.6 OFF OFF OFF 2.6 (16-3.3) 3.0 (1.8-4.3) 650 (400-930)
07 OFF OFF OFF 2.0 OFF OFF OFF 2.0 (1.6-2.7) 2.3 (1.8-3.2) 500 (400-700)
Oper-
ating
Status
Combination of Indoor Units Heating Capacity (kW)
Running Current
(A)
Power Consumption
(W)
ABCDABCD
RATING (Min.-
Max.)
RATING (Min.-
Max.) RATING (Min.-Max.)
4-
Room
09 09 09 09 2.00 2.00 2.00 2.00 8.0 (3.0-9.2) 9.2 (2.6-11.7) 2000 (560-2560)
12 09 07 07 2.74 2.06 1.60 1.60 8.0 (3.0-9.2) 9.2 (2.6-11.7) 2000 (560-2560)
09 09 09 07 2.12 2.12 2.12 1.65 8.0 (3.0-9.2) 9.2 (2.6-11.7) 2000 (560-2560)
12 07 07 07 2.91 1.70 1.70 1.70 8.0 (3.0-9.2) 9.2 (2.6-11.7) 2000 (560-2560)
09 09 07 07 2.25 2.25 1.75 1.75 8.0 (3.0-9.2) 9.2 (2.6-11.7) 2000 (560-2560)
09 07 07 07 2.40 1.87 1.87 1.87 8.0 (3.0-9.2) 9.2 (2.6-11.7) 2000 (560-2560)
07 07 07 07 2.00 2.00 2.00 2.00 8.0 (3.0-9.2) 9.2 (2.6-11.7) 2000 (560-2560)
3-
Room
09 09 09 OFF 2.6 2.6 2.6 OFF 7.8 (2.4-8.8) 11.4 (2.4-12.1) 2500 (520-2650)
12 09 07 OFF 3.3 2.5 2.0 OFF 7.8 (2.4-8.8) 11.4 (2.4-12.1) 2500 (520-2650)
12 07 07 OFF 3.6 2.1 2.1 OFF 7.8 (2.4-8.8) 11.4 (2.4-12.1) 2500 (520-2650)
09 09 07 OFF 2.8 2.8 2.2 OFF 7.8 (2.4-8.8) 11.4 (2.4-12.1) 2500 (520-2650)
09 07 07 OFF 3.1 2.4 2.4 OFF 7.8 (2.4-8.8) 11.4 (2.4-12.1) 2500 (520-2650)
07 07 07 OFF 2.4 2.4 2.4 OFF 7.1 (2.4-8.8) 10.0 (2.4-12.1) 2180 (520-2650)
2-
Room
12 09 OFF OFF 4.2 3.1 OFF OFF 7.3 (1.8-7.5) 11.0 (2.1-11.9) 2400 (450-2600)
12 07 OFF OFF 4.5 2.6 OFF OFF 7.1 (1.8-7.5) 10.9 (2.1-11.9) 2380 (450-2600)
09 09 OFF OFF 3.2 3.2 OFF OFF 6.4 (1.8-7.5) 9.4 (2.1-11.9) 2050 (450-2600)
09 07 OFF OFF 3.4 2.7 OFF OFF 6.1 (1.8-7.5) 8.7 (2.1-11.9) 1900 (450-2600)
07 07 OFF OFF 2.7 2.7 OFF OFF 5.3 (1.8-7.3) 7.2 (2.1-10.5) 1580 (450-2300)
1-
Room
12 OFF OFF OFF 3.8 OFF OFF OFF 3.8 (1.1-5.2) 8.0 (1.8-11.0) 1750 (400-2400)
09 OFF OFF OFF 2.9 OFF OFF OFF 2.9 (1.1-4.0) 5.2 (1.8-9.4) 1130 (400-2050)
07 OFF OFF OFF 2.4 OFF OFF OFF 2.4 (1.1-3.4) 3.7 (1.8-6.6) 800 (400-1450)
Compressor DA220A2F-20L Hermetically sealed DC twin rotary
Fuse 1,101 — QFS-GA065JBZZ(20A,250V)
Fuse 3,4 — QFS-GA062JBZZ(3.15A,250V)
Fuse 5 — QFS-GA063JBZZ(2A,250V)
Fuse 6 — QFS-GA064JBZZ(1A,250V)