Service manual
3 – 11
2 . When one room is not cooled (other rooms are cooled)
Yes
Yes
No
Yes
No
No
No
Yes
No
No
Yes
Yes
S hort circuit of the thermi
stor error
Open circuit of the thermis tor error
Open circuit of s eria l s
ignal line
S hort circuit of seria l s
ignal line
Is the t imer lamp of the
indoor unit in the room
not cooled flas hing ?
Press the OPERATION
button to s ta rt opera ting
the air-conditioner.
(S et the cooling mode
Is the t imer lamp of the
indoor unit in the room
not cooled fla s hing ?
Check that the power
betwe en the termina l
board "N" and "1" of the
indoor unit is AC 230V .
R epair the wiring
bet ween the units.
R eplace the indoor
control PW B.
Replace the thermistor.
Check the failure
sympt om with the failure
diagnos is mode.
R eplace the outdoor control
PWB
or the expansion valve (UNIT A)
or the expansion valve (UNIT B)
or the expansion valve (UNIT C)
or the expansion valve (UNIT D)
Is the re s is ta nc e va lue of the
winding in the fan motor
?
Abnormal fan motor of
indoor unit
The fuse is blown.
R eplace the indoor fan moto
r.
Is the wiring between the
units connected by mistake
or broken ?
R epair the wiring between
the units .
Replace the indoorcontrolPWB.
Is the res is ta nce va lue of the the r
-
mis tor for UN IT A (T H6), U NIT B
(T H7), UNIT C (T H 8) or UN IT D
(T H9)
͠㧕
to 18