Manual
17
Specification
Capacity Table
2-indoor units with AE-X2M14LR
2-indoor units with AE-X2M18KR
2-indoor units with AE-X2M18KR
Outdoor Units
System 2-indoor operation 2-indoor oparation 3-indoor operation 4-indoor operation 4-indoor operation
Model
Outdoor AE-X2M14LR AE-X2M18KR AE-X3M18JR AE-XM24HR AE-XM30GR
Indoor Unit Combination
*4
7+7 9+9 7+7+7 7+7+7+7 9+7+7+7
Capacity
*1
Cool (Min. – Max.) kW 3.80 (1.80 – 4.30) 5.20 (1.80 – 6.00) 5.20 (2.20– 7.00) 7.00 (3.00 – 8.20) 8.40 (4.30 – 9.00)
Heat (Min. – Max.) kW 4.40 (1.90 – 5.40) 5.80 (1.90 – 7.30) 6.8 (2.20 – 8.40) 8.00 (3.00 – 9.20) 9.00 (4.40 – 10.60)
Power Supply
V/Phase/Hz 230/1ø/50 230/1ø/50 230/1ø/50 230/1ø/50 230/1ø/50
Running Current
*1
Cool A 4.1 7.0 (1.6 – 9.4) 6.5 (2.2 –11.3) 10.0 (2.7 – 13.6) 13.7 (4.9 – 16.0)
Heat A 4.4 6.7 (1.7 – 9.6) 7.6 (1.9 – 11.4) 9.2 (2.6 – 11.7) 11.0 (4.3 – 14.0)
Power Input
*1
Cool (Min. – Max.) W 900 (350 – 1,160) 1,530 (350 – 2,050) 1,410 (430 – 2,460) 2,180 (600 – 2,980) 2,990 (1,070 – 3,490)
Heat (Min. – Max.) W 950 (370 – 1,300) 1,450 (370 – 2,100) 1,660 (420 – 2,480) 2,000 (560 – 2,560) 2,400 (940 – 3,060)
Cooling Mde*2 (Average)
SEER 6.4 6.2 6.0 6.2 5.2
Energy Efficiency Class A++ A++ A+ A++ A
Annual Electricity Consumption
*5
kWh/a 207 292 301 393 564
P Design kW 3.8 5.2 5.2 7.0 8.4
Heating Mode
*2
(Average)
SCOP 4.4 4.2 4.1 4.3 3.9
Energy Efficiency Class A+ A+ A+ A+ A
Annual Electricity Consumption
*5
kWh/a 1109 1469 1851 2062 2636
P Design kW 3.5 4.4 5.4 6.3 7.3
Declared Capacity dB(A) 2.8 3.5 4.8 5.4 5.9
Back Up Heating Capacity dB(A) 0.7 0.9 0.6 0.9 1.4
EER
*2
Cool 4.22 3.40 3.69 3.21 2.81
COP
*2
Heat 4.63 4.00 4.10 4.00 3.75
Sound Preassure Level
*3
(Cool)
dB(A) 45 46 46 49 57
Sound Power Level (Cool)
dB 62 62 62 65 68
Dimensions (WxHxD)
mm 890x645x290 890x645x290 890x645x290 890x800x320 890x800x320
Net Weight
kg 51 51 53 64 70
Pipe Diameter
Liquid Side inch 1/4 x 2 1/4 x 2 1/4 x 3 1/4 x 4 1/4 x 4
Gas Side inch 3/8 x 2 3/8 x 2 3/8 x 3 3/8 x 4 3/8 x 3, 3/8 or 1/2 x 1
Min. – Max. Pipe Length (per indoor unit)
m 3 – 25 3 – 25 3 – 25 3 – 20 3 – 20
Maximum Length (total)
m 40 40 50 50 50
Maximum Chargeless Length (total)
m 25 25 30 40 50
Maximum Height Difference
m 10 10 10 10 10
Refrigerant/GWP
*6
kgCO
2
eq. R410A (1975) R410A (1975) R410A (1975) R410A (1975) R410A (1975)
Operating Range (Outdoor)
Cool °C -10 – 43 -10 – 43 21 – 43 21 – 43 21 – 43
Heat °C -15 – 24 -15 – 24 -15 – 24 -15 – 24 -15 – 24
Indoor Units
Wall Mounted Floor Standing Floor/Ceiling
Model
AY-XPM7/XPC9/XPC12PHR
AY-XPC7/9/12JR AY-XPM7/9/12FR AY-XPC18LR GS-XPM9/12/18FGR GS-XPM7/9/12FR
Sound Pressure Level (Hi/Lo)
*3
(Cool)
dB(A)
7PHR:3/26, 9PHR:39/26,
12PHR:42/27
7JR: 36/26, 9JR: 37/26,
12JR: 40/27
7FR: 37/28, 9FR: 39/28,
12FR: 40/29
43/39
9FGR: 38/25, 12FGR: 40/26,
18FGR: 44/35
7FR: 34/27, 9FR: 38/29,
12FR: 39/30
Sound Power Level (Cool) (Hi)
dB
7PHR:53, 9PHR:54, 12PHR:56 7JR: 51, 9JR: 52, 12JR: 56 7FR: 52, 9FR: 54, 12FR: 56
58
9FGR: 53, 12FGR: 54, 18FGR: 60 7FR: 47, 9FR: 52, 12FR: 52
Airflow Volume (Cool) (Hi)
m
3
/min
7PHR:9.4, 9PHR:9.7, 12PHR:10.8 7JR: 8.9, 9JR: 9.1, 12JR: 10.5 7FR: 8.0, 9FR: 8.6, 12FR: 9.8
14.4
9FGR: 9.3, 12FGR: 10.6, 18FGR: 14.2
7FR: 7.5, 9FR: 8.7, 12FR: 10.4
Dimensions
W
mm
920 790 790 1,040 750 1,025
H
290 278 278 325 670 680
D
240 198 198 222 235 212
Net Weight
kg
10 10 10 12 17 31
Operating
status
Indoor unit
combination
Cooling capacity (kW) Heating capacity (kW)
Power input (W)
Rating (Min. – Max.)
A B A B
Rating
(Min. – Max.)
A B
Rating
(Min. – Max.)
Cool Heat
2-indoor
unit
operation
12 9 2.17 1.63 3.8 (1.8 – 4.3) 2.51 1.89 4.4 (1.9 – 5.4) 900 (350 – 1,160) 950 (370 – 1,300)
12 7 2.40 1.40 3.8 (1.8 – 4.3) 2.78 1.62 4.4 (1.9 – 5.4) 900 (350 – 1,160) 950 (370 – 1,300)
9 9 1.90 1.90 3.8 (1.8 – 4.3) 2.20 2.20 4.4 (1.9 – 5.4) 900 (350 – 1,160) 950 (370 – 1,300)
9 7 2.14 1.66 3.8 (1.8 – 4.3) 2.48 1.93 4.4 (1.9 – 5.4) 900 (350 – 1,160) 950 (370 – 1,300)
Operating
status
Indoor unit
combination
Cooling capacity (kW) Heating capacity (kW)
Power input (W)
Rating (Min. – Max.)
A B A B
Rating
(Min. – Max.)
A B
Rating
(Min. – Max.)
Cool Heat
2-indoor
unit
operation
12 12 2.60 2.60 5.2 (1.8 – 6.0) 2.90 2.90 5.8 (1.9 – 7.3) 1,530 (350 – 2,050) 1,450 (370 – 2,100)
12 9 2.97 2.23 5.2 (1.8 – 6.0) 3.31 2.49 5.8 (1.9 – 7.3) 1,530 (350 – 2,050) 1,450 (370 – 2,100)
12 7 3.28 1.92 5.2 (1.8 – 6.0) 3.66 2.14 5.8 (1.9 – 7.3) 1,530 (350 – 2,050) 1,450 (370 – 2,100)
9 9 2.60 2.60 5.2 (1.8 – 6.0) 2.90 2.90 5.8 (1.9 – 7.3) 1,530 (350 – 2,050) 1,450 (370 – 2,100)
9 7 2.64 2.06 4.7 (1.8 – 5.6) 3.04 2.36 5.4 (1.9 – 7.0) 1,340 (350 – 1,830) 1,310 (370 – 2,030)
Operating
status
Indoor unit
combination
Cooling capacity (kW) Heating capacity (kW)
Power input (W)
Rating (Min. – Max.)
A B C A B C
Rating
(Min. – Max.)
A B C
Rating
(Min. – Max.)
Cool Heat
3-indoor
unit
operation
12 9 9 2.08 1.56 1.56 5.2 (2.2 – 7.2) 2.72 2.04 2.04 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)
12 9 7 2.23 1.67 1.30 5.2 (2.2 – 7.2) 2.91 2.19 1.70 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)
12 7 7 2.40 1.40 1.40 5.2 (2.2 – 7.2) 3.14 1.83 1.83 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)
9 9 9 1.73 1.73 1.73 5.2 (2.2 – 7.2) 2.27 2.27 2.27 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)
9 9 7 1.87 1.87 1.46 5.2 (2.2 – 7.2) 2.45 2.45 1.90 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)
9 7 7 2.03 1.58 1.58 5.2 (2.2 – 7.2) 2.66 2.07 2.07 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)
7 7 7 1.73 1.73 1.73 5.2 (2.2 – 7.0) 2.27 2.27 2.27 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)
2-indoor unit
operation
12 12 – 2.50 2.50 – 5.0 (1.9 – 6.5) 3.35 3.35 – 6.7 (1.6 – 8.0) 1,400 (350 – 2,400) 1,970 (380 – 2,670)
12 9 * 2.86 2.14 * 5.0 (1.9 – 6.5) 3.83 2.87 * 6.7 (1.6 – 8.0) 1,400 (350 – 2,400) 1,970 (380 – 2,670)
Operating
status
Indoor unit
combination
Cooling capacity (kW) Heating capacity (kW)
Power input (W)
Rating (Min. – Max.)
A B C A B C
Rating
(Min. – Max.)
A B C
Rating
(Min. – Max.)
Cool Heat
2-indoor
unit
operation
12 7 * 3.16 1.84 * 5.0 (1.9 – 6.4) 4.17 2.43 * 6.6 (1.6 –8.0) 1,400 (350 – 2,380) 1,970 (380 – 2,670)
9 9 * 2.45 2.45 * 4.9 (1.9 – 6.2) 3.10 3.10 * 6.2 (1.6 – 8.0) 1,380 (350 – 2,200) 1,800 (380 – 2.670)
9 7 * 2.53 1.97 * 4.5 (1.9 – 5.7) 3.15 2.45 * 5.6 (1.6 – 7.3) 1,190 (350 – 1,870) 1,550 (380 – 2,310)
7 7 * 2.00 2.00 * 4.0 (1.9 – 5.2) 2.50 2.50 * 5.0 (1.6 – 6.4) 1,000 (350 – 1,550) 1,320 (380 – 1,910)
1-indoor
unit
operation
12 * * 3.40 * * 3.4 (1.4 – 4.0) 4.00 * * 4.0 (1.1 – 5.2) 950 (320 – 1,350) 1,400 (330 – 2,150)
9 * * 2.60 * * 2.6 (1.4 – 3.3) 3.00 * * 3.0 (1.1 – 4.2) 680 (320 – 950) 970 (330 – 1,570)
7 * * 2.00 * * 2.0 (1.4 – 2.7) 2.40 * * 2.4 (1.1 – 3.3) 520 (320 – 710) 720 (330 – 1,130)
Operating status
Indoor unit
combination
Cooling capacity (kW) Heating capacity (kW)
Power input (W)
Rating (Min. – Max.)
A B A B
Rating
(Min. – Max.)
A B
Rating
(Min. – Max.)
Cool Heat
2-indoor unit operation
7 7 1.90 1.90 3.8 (1.8 – 4.3) 2.20 2.20 4.4 (1.9 – 5.4) 900 (350 – 1,160) 950 (370 – 1,300)
1-indoor unit
operation
12 * 3.40 OFF 3.4 (1.4 – 3.3) 3.90 OFF 3.9 (1.2 – 4.6) 910 (320 – 1,320) 1,140 (320 – 1,570)
9 * 2.60 OFF 2.6 (1.4 – 3.3) 3.00 OFF 3.0 (1.2 – 4.2) 660 (320 – 920) 830 (330 – 1,400)
7 * 2.00 OFF 2.0 (1.4 – 2.7) 2.40 OFF 2.4 (1.2 – 3.3) 510 (320 –700) 680 (320 – 1,010)
Operating status
Indoor unit
combination
Cooling capacity (kW) Heating capacity (kW)
Power input (W)
Rating (Min. – Max.)
A B A B
Rating
(Min. – Max.)
A B
Rating
(Min. – Max.)
Cool Heat
2-indoor unit operation
7 7 2.10 2.10 4.2 (1.8 – 5.2) 2.50 2.50 5.0 (1.9 – 6.3) 1,120 (350 – 1,540) 1,170 (370 – 1,700)
1-indoor unit
operation
12 * 3.40 * 3.4 (1.4 – 4.0) 4.00 * 4.0 (1.2 – 5.2) 950 (320 – 1,350) 1,240 (320 – 1,900)
9 * 2.60 * 2.6 (1.4 – 3.3) 3.00 * 3.0 (1.2 – 4.2) 680 (320 – 950) 830 (330 – 1,440)
7 * 2.00 * 2.0 (1.4 – 2.7) 2.40 * 2.4 (1.2 – 3.3) 510 (320 – 700) 680 (320 –1,050)
*1 According to EN14511. *2 According to EN14825. *3 Sound pressure level is measured according to JIS C 9612.
*4 7: AY-XPM7PHR, AY-XPC7JR, AY-XPM7FR, GS-XPM7FR; 9: AY-XPC9PHR, AY-XPC9JR, AY-XPM9FR, GS-XPM9FR, GS-XPM9FGR
*5 Energy consumption “XYZ” kWh per year, based on standardtest results. Actual energy consumption will depend on how theappliance is used and where it is located.
*6 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leakedto the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1 kg of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
* When the Multi inverter type is used to operate two or more indoor units simultaneously, the capacity
of each indoor unit may be lower than that when operating only one indoor unit. Be sure to refer to the
capacity table to select the appropriate models.
Indoor
units
AY-XPM7PHR, AY-XPC7JR, AY-XPM7FR, GS-XPM7FR
AY-XPC9PHR, AY-XPC9JR, AY-XPM9FR, GS-XPM9FR, GS-XPM9FGR
AY-XPC12PHR, AY-XPC12JR, AY-XPM12FR, GS-XPM12FR, GS-XPM12FGR
AY-XPC18LR, GS-XPM18FGR
7
9
12
18
* When connected indoor unit is not in operation.
* When connected indoor unit is not in operation.
* When connected indoor unit is not in operation.
INVERTER
MULTI T YPE