Manual

15
Cassette
NEW
GX-XPC18PR
AE-XM30GR
Features
A wide variety of choices
Sharp’s multi-split air conditioning systems allow you to
combine up to four indoor
units with a single outdoor unit. The indoor units can be wall
mounted types, fl oor/ceiling types,
or fl oor standing types. This wide-ranging choice of indoor
units offers you more fl exible
coordination for each room.
* See the specifi cation table for multi type indoor and outdoor units on page 17.
*1 AE-X2M14LR Representative connection (7+7)
*2 AE-X2M18KR Representative connection (9+9)
* Two indoor units must be connected.
* See the capacity table on page 17 for permissible combinations.
R410A
Compact design for easy installation
Low noise level
Wireless remote control
Energy save setting
Automatic swing louvers
Model
Indoor GX-XPC18PR*
Panel frame AZ-XP18PR
Outdoor AE-XM30GR
Capacity*
1
Cool (Max. – Min.) kW 8.4 (4.3 – 9.0)
Heat (Max. – Min.) kW 9.0 (4.4 – 10.6)
Power Supply
Outdoor V/Phase/Hz 230/single/50
Sound Pressure Level
*2
Indoor (Hi/Lo) dB(A) 42/40
Sound Power Level
Indoor (Hi) 55
Dimensions
Indoor (WxHxD) mm 840x265x840
Outdoor (WxHxD) mm 950x60x950
Weight
Indoor kg 20
Pipe Diameter
Liquid Side inch 1/4
Gas Side inch 1/2
Min. – Max. Pipe Lenght (per Indoor Unit)
m 3 – 20
Maximum Length (total)
m 40
Max. Height Difference
m 10
Max. Chargless Lenght (total)
m 40
Refrigerant (GWP
*3
)
kgCO
2
eq. R410A (1975)
*1 According to EN14511/ tested 2 units of GX-XPC8PR with AE-XM30GR.
*2 Sound pressure level is measured according to JIS C 9612.
*3 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP)
would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fl uid with a GWP equal to 1975. This means that if 1 kg of this
refrigerant fl uid would be leaked to the atmosphere, the impact on global warming would be 1975 times
higher than 1 kg of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself
or disassemble the product yourself and always ask a professional.
* This product is designed to have two cassette units connecting to AE-XM30GR only.
Outdoor unit lineup
AE-X2M14LR
Example of indoor unit combinations
7 9
AE-X2M18KR
2 indoor units
Outdoor Unit Indoor Unit
Cooling Operation Heating Operation
Capacity (kW)
(Min. – Max.)
SEER
Capacity (kW)
(Min. – Max.)
SCOP
AE-X2M14LR
Cool/Heat/Dry
12 + 7 3.8 (1.8 – 4.3)
6.4
*1
4.4 (1.9 – 5.4)
4.4
*1
9 + 9 3.8 (1.8 – 4.3) 4.4 (1.9 – 5.4)
7 + 7 3.8 (1.8 – 4.3) 4.4 (1.9 – 5.4)
AE-X2M18KR
Cool/Heat/Dry
12 + 7 5.2 (1.8 – 6.0)
6.2
*2
5.8 (1.9 – 7.3)
4.2
*2
9 + 9 5.2 (1.8 – 6.0) 5.8 (1.9 – 7.3)
9 + 7 4.7 (1.8 – 5.6) 5.4 (1.9 – 7.0)
2 ROOMS
R410A
Connection indoor units
Wall mounted
AY-XPM7FR
Wall mounted
AY-XPM9FR
Wall mounted
AY-XPM12FR
Wall mounted
AY-XPC7JR
Wall mounted
AY-XPC9JR
Wall mounted
AY-XPC12JR
Wall mounted
AY-XPM7PHR
NEW
Wall mounted
AY-XPC9PHR
NEW
Wall mounted
AY-XPC12PHR
Wall mounted
AY-XPC18LR
Floor standing
GS-XPM9FGR
Floor standing
GS-XPM12FGR
Floor standing
GS-XPM18FGR
For AE-XM30GR only*
Floor/ceiling
GS-XPM7FR
Floor/ceiling
GS-XPM9FR
Floor/ceiling
GS-XPM12FR
NEW
GS-XPC18PR
INVERTER
MULTI T YPE