Manual

9
Deluxe
AY-XPC9/12JR
Features
Cool/Dry/Heat
Outdoor unit
AE-X9JR AE-X12JR
R410A
Can be used singly
or in a multi split system
Coanda Airfl ow System
Model
AY-XPC9JR
2.50 (0.90 – 3.00) 3.20 (0.90 – 5.00)5.1 3.9
Cooling operation Heating operation
Capacity (kW)
(Min. – Max.)
Capacity (kW)
(Min. – Max.)
SEER SCOP
AY-XPC12JR
3.50 (0.90 – 3.80) 4.00 (0.90 – 5.70)5.1 4.0
A
+A
A
A
Specifi cation
Model Indoor
AY-XPC9JR AY-XPC12JR
Outdoor
AE-X9JR AE-X12JR
Preformance
*1
Cooling
Energy Effi ciency Class A A
SEER 5.1 5.1
Pdesign kW 2.5 3.5
Capacity (Min. – Max.) kW 2.50 (0.90 – 3.00) 3.50 (0.90 – 3.80)
Input (Min. – Max.) W 625 (200 – 900) 1,090 (200 – 1,300)
Annual electricity consumption
*2
kWh/a 171 239
Heating
(Average
Climate)
Energy Effi ciency Class A A+
SCOP 3.9 4.0
Pdesign kW 3.2 3.5
Capacity (Min. – Max.) kW 3.20 (0.90 – 5.00) 4.00 (0.90 – 5.70)
Input (Min. – Max.) W 760 (180 – 1,450) 1,020 (180 – 1,650)
Annual electricity consumption
*2
kWh/a 1,126 1,221
Nominal Effi ciency
*3
EER 4.00 3.21
COP 4.21 3.92
Nominal Current
*3
Cooling A 3.1 4.9
Heating A 3.7 4.6
Sound Pressure Level
*4
(Cool)
Indoor (Hi/Lo) dB(A) 37/26 40/27
Outdoor db(A) 45 48
Sound Power Level (Cool)
Indoor (Hi) 52 56
Outdoor 58 61
Airfl ow Volume (Hi, Cool)
m
3
/min 9.1 10.5
Operation Range (Outdooor)
Coolong °C -10 – 46 -10 – 46
Heating °C -15 – 24 -15 – 24
Model Indoor
AY-XPC9JR AY-XPC12JR
Outdoor
AE-X9JR AE-X12JR
Power Supply Outdoor
V/Phase/Hz 220 – 240/single/50 220 – 240/single/50
Dimensions Indoor (WxHxD)
mm 790x278x198 790x278x198
Outdoor (WxHxD)
mm 730x540x250 730x540x250
Weight Indoor
kg 10 10
Outdoor
kg 33 33
Min. – Max. Pipe Lenght
m 1 – 15 1 – 15
Max. Height Difference
m 7 7
Max. Chargless Lenght
m 10 10
Pipe Diameter Liquid Side
inch 1/4 1/4
Gas Side
inch 3/8 3/8
Refrigerant (GWP
*5
)
kgCO
2
eq. R410A (1975) R410A (1975)
*1 According to EN14825
*2 Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy
consumption will depend on how the appliance is used and where it is located.
*3 According to EN14511
*4 Sound pressure level is measured according to JIS C 9612.
*5 Refrigerant leakage contributes to climate change. Refrigerant with lower global
warming potential (GWP) would contribute less to global warming than a refrigerant
with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fl uid
with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked
to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg
of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.