AY-X9XEJ / AE-X9XEJ AY-X12XEJ / AE-X12XEJ
AND R290 1 2 5 6 7 8 12 18 19 22 31 32
and R290 and R290 and R290 and R290 and R290
P 2
3
4
NAMES OF PARTS INDOOR UNIT No. Description 1 Front panel 2 Air filter 3 Optional filter (if installed) 4 LED Display 5 Signal receiver 6 Terminal block cover 7 Ionizer generator(Not equipped on this model) 8 Deflectors 1 10 6 11 9 Emergency button 10 Indoor unit rating label (Stick position optional) 11 Airflow direction louver 12 Remote controller 4-5 2-3 10 8 7 9 12 Note: The deflectors are positioned mannually and placed under the flap.
INDOOR UNIT DISPLAY 3 2 1 No. Led Function 1 SLEEP SLEEP mode 2 Temperature display (if present) /Error code (1) Lights up during Timer operation when the air conditioner is operational (2)Displays the malfunction code when fault occurs. 3 TIMER Lights up during Timer operation. The shape and position of switches and indicators may be different according to the model, but their function is the same.
7
REMOTE CONTROLLER No. Button 1 2 OPTION Function To turn on or off the air conditioner . To activate or deactivate optional function(Check below table). 3 To decrease temperature, time setting or choose the function. 4 To increase temperature , time setting or choose the function. 5 ECO 6 TURBO Press this button to activate/deactivate the Super function which enables the unit to reach the preset temperature in the shortest time.
AUTO COOL DRY FAN HEAT ECO SLEEP TIMER I FEEL HEALTH MILDEW CLEAN DISPLAY 8 CH WIND FREE GEN MODE 1 2 3 4 5 6 7 8 9 10 You will hear a beep when you press the following buttons or select the following optional functions, though the actual model does not have this function.
REMOTE CONTROLLER Remote controller DISPLAY Meaning of symbols on the liquid crystal display Symbols No.
Replacement of Batteries Remove the battery cover plate from the rear of the remote controller, by sliding it in the direction of the arrow. Install the batteries according the direction (+and -)shown on the Remote Controller. Reinstall the battery cover by sliding it into place. Use 2 LR 03 AAA (1.5V) batteries . Do not use rechargeable batteries . Replace the old batteries with new ones of the same type when the display is no longer legible. Do not dispose batteries as unsorted municipal waste.
OPERATING INSTRUCTIONS The air sucked by the fan enters from the grill and passes through the filter, then it is cooled/dehumidified or heated through the heat exchanger. Filter Heat Exchanger The direction of the air outlet is motorized up and down by flaps, and manually moved right and left by the vertical deflectors, for some models, the vertical deflectors could be controlled by motor as well. Fan “SWING” CONTROL OF THE AIR FLOW 1.Press the button to activate the FLAP . 2.
OPERATING INSTRUCTIONS COOLING MODE COOL The cooling function allows the air conditioner to cool the room and at the same time reduces air humidity. To activate the cooling function ( COOL ) , press the MODE button until the symbol COOL appears on the display. The cooling function is activated by setting the button or at a temperature lower than that of the room.
OPERATING INSTRUCTIONS FAN MODE(Not FAN button) FAN The air conditioner works in only circulation. To set the FAN mode , Press MODE until FAN appears on the display. To optimize the function of the air conditioner, adjust the temperature(1), the speed (2) and the direction of the air flow (3) by pressing the buttons indicated. AUTO MODE AUTO Automatic mode. To activate the AUTO mode of operation, press the MODE button on the remote controller until the symbol AUTO appears on the display.
OPERATING INSTRUCTIONS ECO function ECO In this mode the appliance automatically sets the operation to achieve energy savings. 1. Press the "ON / OFF" button to turn on appliance and select a COOLING / HEATING mode. 2. Press the "ECO" button, the appliance will run in ECO mode. 3. Press the "ECO" button again will cancel the mode, "ECO" will no longer be shown on the display. NOTE: The ECO function is available in COOLING and HEATING modes.
OPERATING INSTRUCTIONS TIMER function TIMER To set the automatic switch-on /off of the air conditioner. Timer setting/change/cancel: 1. Press OPTION at the first time , select the Timer by pressing the button or until symbol TIMER is flashing; 2. Press OPTION again, the data symbol like and TIMER will be flashing; 3. To set the timer or change the timer: (1)Press the button or to set the expected timer (Increase or decrease at half-hour intervals) the symbols h and TIMER both are flashing.
OPERATING INSTRUCTIONS SELF-CLEAN function CLEAN This function helps carry away the accumulated dirt, bacteria,etc from the indoor hear exchanger. Press OPTION at the first time while air conditioner is turned off, select the CLEAN by pressing the button or until symbol CLEAN is flashing; Press OPTION again to activate the CLEAN function, and CLEAN appears on the display.Do it again to deactivate this function. 1. This function help carry away the accumulated dirt, bacteria, etc from the evaporator. 2.
The air conditioner is programmed for comfortable and suitable living conditions as below if used outside the conditions, certain safety protection features might come into effect.
19
20
21
22
23
Refrigerant piping connection 1 The piping can be run in the 3 directions indicated by numbers in the picture . When the piping is run in direction 1or3, cut a notch along the groove on the side of the indoor unit with a cutter. Run the piping in the direction of the wall hole and bind the copper pipes , the drain pipe and the power cables together with the tape with the drain pipe at the bottom, so that water can flow freely.
25
INSTALLATION MANUAL---Installation of the outdoor unit ELECTRICAL CONNECTIONS wiring diagram on the back of the cover 1. Remove the handle on the right side plate of outdoor unit. 2. Connect the power connection cord to the terminal board. Wiring should fit that of indoor unit. 3. Fix the power connection cord with wire clamp. 4. Confirm if the wire has been fixed properly. 5. An efficient earth connection must be ensured. 6. Recover the handle.
27
INVERTER TYPE 9k 12k 18k 24k 1/4 ( 6) 3/8 ( 9.52) 1/4 ( 6) 1/2 ( 12) 1/4 ( 6) 1/2 ( 12) 1/4 ( 6) 5/8 ( 15.88) Length of pipe with standard charge 3m 4m 5m 5m Maximum distance between indoor and outdoor unit 15m 15m 15m 15m 20g/m 20g/m 30g/m 30g/m Max. diff.
Front panel Wiring diagram Wiring diagram Outdoor handle cover 29
30
antidust filter 31
32