Service manual

AR-203E/5420/M200/M201 SIMULATION, TROUBLE CODES 10 - 7
08 01 Developing bias [Function]
When [OK]/[ENTER]/[START] key is pressed, the developing bias signal is turned ON for 30sec.
When, however, an actual output value is measured, use simulation 25-01.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation] (AR-M200/M201)
02 Main charger (Grid high) [Function]
When [OK]/[ENTER]/[START] key is pressed, the main charger is outputted for 30sec in the grid
voltage HIGH move.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation] (AR-M200/M201)
03 Grid voltage (Low) [Function]
When [OK]/[ENTER]/[START] key is pressed, the main charger is outputted for 30sec in the grid
voltage LOW move.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation] (AR-M200/M201)
06 Transfer charger [Function]
When [OK]/[ENTER]/[START] key is pressed, the transfer charger is outputted for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation] (AR-M200/M201)
09 01 Duplex motor normal
rotation operation check
(AR-M201 only)
[Function]
Use the duplex motor Bios to drive the duplex motor in the normal direction (paper exit direc-
tion) for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
02 Duplex motor reverse
operation check
(AR-M201 only)
[Function]
Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
04 Duplex motor rotation speed
adjustment (AR-M201 only)
[Function]
When this simulation is executed, the currently set value is displayed.
Enter the adjustment value with [Numeric] key and press [OK]/[ENTER]/[START] key. The
entered value is stored and the machine goes into the sub code entry standby mode. The
greater the set value is, the higher the speed is. The smaller the set value is, the lower the
speed is. (Setting range: 1 - 13, Default: 8)
[Operation]
Main
code
Sub
code
Contents Details of function/operation
1) Initial display
08-01 DVLP BIAS SET.
EXECUTING...
1) Initial display
08-02 MHV(H) SET.
EXECUTING...
1) Initial display
08-03 MHV(L) SET.
EXECUTING...
1) Initial display
08-06 THV SET.
EXECUTING...
1) Initial display
09-01 DPLX ROT.
EXECUTING...
1) Initial display
09-02 DPLX ROT.REV.
EXECUTING...
1) Initial display 2) [Numeric] key 3) [OK]/[ENTER]/[START]
key
09-04 DPLX ROT.SPEED
8( 1-13)
09-04 DPLX ROT.SPEED
7( 1-13)
09-04 DPLX ROT.SPEED
7( 1-13)