Service manual
AR-203E/5420/M200/M201 SIMULATION, TROUBLE CODES 10 - 1
[10] SIMULATION, TROUBLE CODES
1. Entering the simulation mode
To enter the serviceman simulation mode, press the keys as fol-
lows:
AR-203E/AR-5420
[Clear] key
→ Exposure mode selector key → [Clear] key →
Exposure mode selector key
AR-M200/AR-M201
[#] key
→ [∗] key → [Clear] key → [∗] key
To cancel the simulation mode, press the [Clear All] key.
2. Key rule
AR-203E/AR-5420
AR-M200/AR-M201
3. List of simulations
[ ] [ ] key: Entry of MAIN CODE/SUB CODE
Setting of the adjustment values for the
adjustment-related simulations
When [%] key is pressed simultaneously, the
value is displayed in the descending
sequence such as [0]
→ [9], not as [0] → [1].
[START] key: Settlement
<In case of simulations for print>
[START] key: Settlement / Print
[Exposure mode
selector] key: Selection of an item
[Clear] key: (Interrupting operation check) Returns to the
upper hierarchy.
On the initial display (00-00), it terminates the
simulation.
Exits from the simulation mode.
For a simulation of adjustment, the display
returns to the initial display (00-00).
[Numeric] key: Entry of MAIN CODE/SUB CODE
Selection of an item
Setup of an adjustment value in case of
simulations for adjustment
[ ] [ ] key: Selection of MAIN CODE/SUB CODE
Selection of an item
[OK]/[ENTER]/
[START] key: Settlement
<In case of simulations for print>
[OK]/[ENTER] key: Settlement (Without print)
[START] key: Settlement / Print
[Clear] key: (Interrupting operation check) Returns to the
upper hierarchy.
In case of simulation of operation check,
terminates the operations.
[Clear All] key: Exits from the simulation mode.
For a simulation of adjustment, the display
returns to the initial display (00-00).
Sim
No.
Sub
code
Operation
01 01 Mirror scan operation
02 Mirror home position sensor (MHPS) status display
06 Aging of mirror scanning
02 01 SPF/RSPF aging operation (Only the AR-203E/
M200/M201 with the SPF/RSPF installed)
02
SPF/RSPF sensor status display (Only the
AR-203E/M200/M201 with the SPF/RSPF installed)
02 03 SPF/RSPF Motor ON (Only the AR-203E/M200/
M201 with the SPF/RSPF installed)
06 Resist clutch ON (SPF) (AR-203E only)
08 RSPF paper feed solenoid operation check
(Only the AR-M200/M201 with the RSPF installed)
09 RSPF reverse solenoid operation check
(Only the AR-M200/M201 with the RSPF installed)
03 03 Shifter operation check (AR-M200/M201)
05 01 Operation panel display check
02 Fusing lamp, cooling fan operation check
03 Copy lamp ON
06 01 Paper feed solenoid ON
02 Resist solenoid ON
07 01 Warm-up display and aging with jam
06 Intermittent aging
08 Shift to copy with the warm-up display
08 01 Developing bias
02 Main charger (Grid high)
03 Grid voltage (Low)
06 Transfer charger
09 01 Duplex motor normal rotation operation check
(AR-M201 only)
02 Duplex motor reverse operation check
(AR-M201 only)
04 Duplex motor rotation speed adjustment
(AR-M201 only)
10 Toner motor aging
14 Cancel of troubles other than U2
16 Cancel of U2 trouble
20 01 Maintenance counter clear
21 01 Maintenance cycle setting
22 01 Maintenance counter display
02 Maintenance preset display
04 JAM total counter display
05 Total counter display
06 Developer counter display
08 SPF/RSPF counter display (Only the AR-203E/
M200/M201 with the SPF/RSPF installed)
11 FAX-related counter display
(Executable only when the FAX is installed.)
12 Drum counter display
13 CRUM type display
14 ROM version display
16 Duplex counter display (AR-M201 only)
17 Copy counter display
18 Printer counter display
19 Scanner mode counter display
(AR-203E/M200/M201)
21 Scanner counter display
22
SPF/RSPF JAM counter display (Only the
AR-203E/M200/M201 with the SPF/RSPF installed)
24 01 JAM total counter clear
04 SPF/RSPF counter clear (Only the AR-203E/
M200/M201 with the SPF/RSPF installed)
05 Duplex counter clear (AR-M201 only)
06 Developer counter clear
07 Drum counter clear
08 Copy counter clear
09 Printer counter clear
10 FAX counter clear
(Executable only when the FAX is installed.)
13 Scanner counter clear
14
SPF/RSPF JAM total counter clear (Only the
AR-203E/M200/M201 with the SPF/RSPF installed)
Sim
No.
Sub
code
Operation