Service manual
AR-203E/5420/M200/M201 SIMULATION, TROUBLE CODES 10 - 41
B. Details of trouble codes
L3 00 Scanner return trouble
L4 01 Main motor lock detection
32 Exhaust fan motor lock detection trouble
L6 10 Polygon motor lock detection
U1 03 FAX board battery error
U2 04 EEPROM read/write error (Serial communication
error)
11 Counter check sum error (EEPROM)
40 CRUM chip communication error
Main
code
Sub
code
Details of trouble
E1 00 Content IMC communication trouble
Detail An abnormality occurs in communication
between the CPU and the IMC.
Cause IMC abnormality
IMC memory defect/data abnormality
Check
and
remedy
Replace the MCU PWB with new one.
10 Content IMC trouble
Detail An abnormality occurs in the IMC.
Cause USB chip error/CODEC error on the IMC.
Check
and
remedy
Replace the MCU PWB with a new one.
13 Content IMC flash ROM error
Detail An abnormality occurs in the IMC flash
ROM.
Cause IMC abnormality
Check
and
remedy
Replace the MCU PWB with a new one.
If downloading of the program is abnormally
terminated, it may cause an error. Download
the program again to avoid this.
81 Content IMC communication interface error (Parity)
Detail A parity error occurs in communication
between the CPU and the IMC.
Cause IMC abnormality
IMC memory defect/data abnormality
Check
and
remedy
Replace the MCU PWB with new one.
E1 82 Content IMC communication interface error
(Overrun)
Detail An overrun error occurs in communication
between the CPU and the IMC.
Cause IMC abnormality
IMC memory defect/data abnormality.
Check
and
remedy
Replace the MCU PWB with new one.
84 Content IMC communication interface error
(Framing)
Detail A framing error occurs in communication
between the CPU and the IMC.
Cause IMC abnormality
IMC memory defect/data abnormality.
Check
and
remedy
Replace the MCU PWB with new one.
Main
code
Sub
code
Details of trouble
E7 01 Content Duplex model memory setup error, memory
not-detected error
Detail The memory is not set properly or the
memory capacity is not set to the duplex
setup (6M).
Check
and
remedy
Set SIM 26-39 code number to 2.
02 Content LSU trouble
Detail The BD signal from the LSU cannot be
detected in a certain cycle. (Always OFF or
always ON)
Cause LSU connector or LSU harness defect or
disconnection
Polygon motor rotation abnormality
Laser beams are not generated.
MCU PWB abnormality.
Check
and
remedy
Check connection of the LSU connector.
Execute SIM 61-03 to check the LSU
operations.
Check that the polygon motor rotates
normally.
Check that the laser emitting diode
generates laser beams.
Replace the LSU unit.
Replace the MCU PWB.
10 Content Shading trouble (Black correction)
Detail The CCD black scan level is abnormal when
the shading.
Cause Improper connection of the CCD unit flat
cable
CCD unit abnormality
MCU PWB abnormality
Check
and
remedy
Check connection of the CCD unit flat cable.
Check the CCD unit.
11 Content Shading trouble (White correction)
Detail The CCD white scan level is abnormal when
the shading.
Cause Improper connection of the CCD unit flat
cable
Dirt on the mirror, the lens, and the reference
white plate
Copy lamp lighting abnormality
CCD unit abnormality
MCU PWB abnormality
(When occurred in the SPF/RSPF scan
position.)
Improper installation of the mirror unit
Check
and
remedy
Clean the mirror, lens, and the reference
white plate.
Check the light quantity and lighting status of
the copy lamp (SIM 05-03).
Check the MCU PWB.
16 Content Abnormal laser output
Detail When the laser output is stopped, HSYNC is
detected.
Cause Laser abnormality
MCU PWB abnormality.
Check
and
remedy
Check the laser emitting diode operation.
Replace the MCU PWB.
Main
code
Sub
code
Details of trouble