Service manual
AR-P17 SIMULATION 5 - 1
[5] SIMULATION
1. Operating procedures and operations
* Entering the simulation mode
1) #/P key (program) ON
→ Asterisk (*) key ON → CLEAR key ON →
Asterisk (*) key ON → Ready for input of a main code of simulation
2) Entering a main code with the 10-key
→ START key ON
3) Entering a sub code with the 10-key
→ START key ON
4) Select an item with the scroll key and the item key.
5) The machine enters the mode corresponding to the selected item.
Press START key to start the simulation operation.
To cancel the current simulation mode or to change the main code
and the sub code, press the CUSTOM SETTINGS key.
* Canceling the simulation mode to return to the normal mode
1) Press CLEAR ALL key.
2. Simulation code list
3. Details
Operation/procedure
Each counter is displayed.
The counter display is in 7 digits.
Operation/procedure
1. Select the counter to be cleared with the 10-key.
2. Press the [START] key.
The confirmation menu is shown.
3. Select "1: YES."
1: YES (Cleared)
2: NO (Not cleared) (Default)
Operation/procedure
1. Press the [START] key.
"PLEASE SEND DATA" is displayed.
2. Data are sent from the PC (MS-DOS) by use of "fcopy" command
(FCOPY: file name). (Refer the “[7] FLASH ROM VERSION UP
PROCEDURE”)
Used to overwrite and check the flash device while displaying its
process status.
After completion, the result is displayed.
3. Press the [CA] key to cancel the simulation and reset.
* Execution of the simulation which performs communication with the
PCL board is inhibited until Notice Page storage is completed. (Only
when the serviceman call error occurs.)
In the other case than the serviceman call error, entering the simula-
tion is inhibited during the system check operation is displayed.
Code
Function
Main Sub
22 1 Used to check the counter value of each section.
24 9 Used to clear the printer counter and other
counters. (The counter is cleared after completion
of maintenance.)
67 14 Used to check write/comparison of flash programs.
22
22-1
Purpose Adjustment/setting/operation data output/check
(display/print)
Function
(Purpose)
Used to check the counter value of each section.
Item Counter
TOTAL Total
MAINTENANCE Maintenance
DEVE Developer counter *1
DRUM Drum counter
COPY Copy counter
PRINTER Printer counter
IMC IMC counter
DUPLEX Duplex counter
OTHERS The other counters
FAX SEND FAX Send counter
FAX RCV FAX receive counter
FAX OUTPUT FAX print counter
24-9
Purpose Data clear
Function
(Purpose)
Used to clear the printer counter and other counters.
(The counter is cleared after completion of
maintenance.)
Section Printer
Item Counter Printer
Item Content
1 PRINTER
Printer counter
2IMC
IMC counter
3DUPLEX
DUPLEX counter
4OTHERS
The other counters
67-14
Purpose Flash ROM version up
Function
(Purpose)
Used to check write/comparison of flash programs.
Section Printer
Item Operation
(Flash Device)
PROGRAM
BOOTROM
PS KANJI FONT
ESC/P KANJI FONT
OPTION FONT
(Processing state)
RECEIVE
ERASE
WRITE
VERIFY