Service manual

AR-P17 SETTING AND ADJUSTMENTS 4 - 3
D. Function cancel display
When the diag menu or the key operator program menu is displayed,
the current machine state (the key is canceled or not) is displayed.
Display content
ON: The function lock is working.
OFF: The function lock is canceled.
Regardless of the display position
4. Key operator program list
Key operator programs Set value (: Default value) Remarks
Print settings
Default settings Prohibit notice page printing ON / OFF
Print density level 1 / 2 / 3 / 4 / 5
Prohibit test page printing ON / OFF
Rotated print ON / OFF
Forced output of print ON / OFF
Exclude bypass-tray from ATS ON / OFF
Disable default setting changes ON / OFF
Interface settings Hexadecimal dump mode ON / OFF
I/O timeout 1 999 (Increment of 1sec.) 60 (sec.)
Parallel port emulation switching Auto∗ / PostScript (When the PS3
expansion kit is installed.) / PCL
USB port emulation switching Auto∗ / PostScript (When the PS3
expansion kit is installed.) / PCL
Network port emulation switching Auto∗ / PostScript (When the PS3
expansion kit is installed.) / PCL
Port switching method Switch at end of job / Switch after I/O
timeout
Enable parallel port ON / OFF
Enable USB port ON / OFF
Enable network port ON / OFF
Enable ECP ON / OFF
Network settings
(When the print server
card installed.)
IP address
setting
DHCP
ON / OFF To enable the changed setup, the
power must be rebooted.
*1) Displayed when the AR-NC5J is
installed. Not displayed when only
the AR-P17 is installed.
IP address
ON / OFF
IP subnet mask
ON / OFF
IP gate way ON / OFF
Enable TCP/IP *
1)
ON/ OFF
Enable NetWare *
1)
ON / OFF
Enable EtherTalk *
1)
ON / OFF
Enable NetBEUI *
1)
ON / OFF
Reset the NIC
Initialise and/or store
settings
Restore factory default
Store current configuration
Restore configuration
To enable the changed setup, the
power must be rebooted.