Service manual
AR-M208 SIMULATION 8 - 14
Operation/procedure
The network scanner is checked.
When [OK] key is pressed, "Please Send Data" and "READY" are dis-
played, and then ftp is booted from MS-DOS.
Put the file name, and data are transmitted from the PC.
The process is displayed. Check the display.
After completion, the result is displayed.
(It takes a little time to display READY.)
Pressing [CA] key cancels the simulation resets the operation.
* Execution is inhibited until GDI or PCL board is securely installed.
(Because the board is detected by the software.)
Note: Executable only when PCL and NIC are installed.
67-20
Function (Purpose) Used to check the network connection when
the scan option is installed.
(1) (2) (3)
(Normal end screen) (Abnormal end screen)
(TEST DATA)
TEST DATA
(Process status)
RECEIVE
TESTING
Sim67-20 SCAN TEST
PRESS OK KEY
Sim67-20 SCAN TEST
Please Send Data
READY
Sim67-20 SCAN TEST
TEST DATA
RECEIVE
Sim67-20 SCAN TEST
COMPLETE
Sim67-20 SCAN TEST
ERROR