AR-M208 SIMULATION 8 - 7
Operation/procedure
Press the [OK] key.
The scanner mode counter and the number of send of the scanner are
cleared.
* Execution is inhibited until GDI or PCL board is securely installed.
(Because the board is detected by the software.)
Operation/procedure
The operation of the drive system is checked.
Toner density control sensor value is displayed.
Select the mode with the 10-key and press the [OK] key, and the main
motor will rotate and the toner concentration control sensor value will
be displayed.
After execution, interruption cannot be made for about 7 sec. ([CA] key,
[INTERRUPT] key, and [BACK] key are invalid.)
* 1200dpi: Disabled
* Even though in toner END, if no other error (including cover open)
occurs after supplying power, execution of this command is allowed.
Operation/procedure
Select the destination.
Operation/procedure
The current setup is displayed with ON or OFF.
Enter an input (20 digits) of the E-MAIL RIC soft key and press the
[OK] key, and the collating result is displayed with OK or NG.
After canceling the simulation, if OK, the E-MAIL RIC function is
enable; if NG, the E-MAIL RIC function is disabled.
This setting must be reset after the simulation cancel.
* Execution is inhibited until GDI or PCL board is securely installed.
(Because the board is detected by the software.)
Note: Executable only when the PCL/NIC is installed.
Error code Name Sensor name
Paper Reached/
Not reached to
Sensor
PI_TOP
SPF paper-in
lead edge jam
SPF P-IN sensor Not reached
PI_END
SPF paper-in rear
edge jam
SPF P-IN sensor Reached
JAM_REV
SPF duplex
reversion jam
SPF P-IN sensor Not reached
(paper after
reversion)
PO_TOP
SPF paper-out
lead edge jam
SPF P-IN sensor Reached, P-
OUT not
reached
PO_END
SPF paper-out
rear edge jam
SPF P-OUT
sensor
Reached, P-IN
is passed (OFF).
ORG_LONG
SPF long size
error
SPF P-OUT
sensor
Reached
SPF P-IN sensor Reached
ORG_SHORT
SPF short size
error
SPF P-IN sensor Pass (OFF at
JAM)
24
24-15
Purpose Data clear
Function
(Purpose)
Used to clear the scanner mode counter.
Item Counter
(Initial screen) (Process check screen)
25
25-1
Purpose Operation test/check
Function
(Purpose)
Used to check the operation of the main drive
(excluding the scanner section) and to check the
operation of the toner concentration sensor. (The toner
concentration sensor output can be monitored.)
Section DRIVE
Item Operation
Sim24-15 COUNTERCLR
SCANNER MODE
COUNTER CLEAR
PRESS OK KEY
Sim24-15 COUNTERCLR
SCANNER MODE
COUNTER CLEAR
ARE YOU SURE?
(Initial screen) (Executing screen)
26
26-6
Purpose Setting
Function (Purpose) Used to set the specifications depending on
the destination.
Item Specifications Destination
Display
items
Content
Setting
range
Default
0:JAPAN
Japan 0-13 0
1:SEC
SEC
2:SECL
SECL
3:SEEG
SEEG
4:SUK
SUK
5:SCA
SCA
6:SEF
SEF
7:INEG
EX inch series
8:ABEG
EX AB series
9:INEF
EX inch series (FC)
10:ABEF
EX AB series (FC)
11:CHINESE
China
12:TAIWAN
Taiwan
13:SEEG2
SEEG2
26-12
Function
(Purpose)
Used to input the Software Key for E-MAIL RIC.
(Initial screen) (In case of OK) (In case of NG)
Sim25-1 MAIN MOTOR
1:600dpi
2:1200dpi
EXEC 2
Sim25-1 MAIN MOTOR
1:600dpi
2:1200dpi
[128]
EXEC 1
Sim26-6 DESTINATION
DESTINATION 0
(0:JAPAN 1:SEC
2:SECL 3:SEEG 4:SUK
1/3 [ 0- 13] 0
Sim26-12 E-MAIL KEY
E-MAIL KEY ON
----------
----------
Sim26-12 E-MAIL KEY
E-MAIL KEY OK
----------
----------
Sim26-12 E-MAIL KEY
E-MAIL KEY NG
----------
----------