AR-M208 SIMULATION 8 - 2
During execution, [EXEC] is highlighted. Under this state, press the
[BACK] key to interrupt the operation.
The finisher main motor operates for 10sec, the staple motor 5 times,
the tray lift-up motor one reciprocating operation, other motors max. 20
reciprocating operations from the home position, the solenoid repeats
500msec ON and 500msec OFF 20 times.
The staple operation motor operates only when there is no cartridge
installed.
Note:Executable only when the finisher is installed.
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
(
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
* SUPER PHOTO (5:) cannot be executed.
When [OK] or [START] key is pressed, a caution buzzer sounds.
(Only the adjustment value can be entered.)
The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd number + 1 is displayed after
pressing [OK] key.
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
The input value is in the increment of –25V.
(
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
* SUPER PHOTO (5:) cannot be executed.
When [OK] or [START] key is pressed, a caution buzzer sounds.
(Only the adjustment value can be entered.)
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
(Initial screen) (Executing screen)
1:JGM1
Side guide plate drive motor
2:JGM2
Rear edge plate drive motor
3:FM-600
Finisher main motor (600dpi)
4:FM-1200
Finisher main motot (1200dpi) Disabled
5:EVM
Tray lift-up motor
6:OFM
Tray offset motor
7:STM
Staple operation motor
8:OGSLR
Transport selection gate solenoid (R)
9:OGSLL
Transport selection gate solenoid (L)
10:JGSL1
Rear edge plate drive solenoid
11:JGSL2
Upper alignment plate drive solenoid
12:SHTSL
Shutter drive solenoid
13:T2SCL
Paper exit roller clutch
14:STGSL
Paper holding solenoid
8
8-1
Purpose Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in each copy mode and the
control circuit.
Section Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
(Initial screen) (Input/Selection screen) (Executing screen)
Display items Content
Installation
range
Default
1:AE
AE (
) 200-550 400 (–400V)
2:TEXT
Character 450 (–450V)
3:TEXT/PHOTO
Character/Photo 450 (–450V)
4:PHOTO
Photo 450 (–450V)
5:SUPER PHOTO *
Super photo Disabled
6:TONER SAVE
Toner save 376 (–376V)
Sim3-3 OUTPUT CHECK
1:JGM1 4:FM-1200
2:JGM2 5:EVM
3:FM-600 6:OFM
1/3 EXEC
Sim3-3 OUTPUT CHECK
7:STM 10:JGSL1
8:OGSLR 11:JGSL2
9:OGSLL 12:SHTSL
2/3 EXEC 8
Sim8-1 DV BIAS COPY
1:AE 400
2:TEXT 450
3:TEXT/PHOTO 450
1/2
Sim8-1 DV BIAS COPY
5:SUPER PHOTO 400
EXEC [200-550] 400
Sim8-1 DV BIAS COPY
5:SUPER PHOTO 400
EXEC [200-550] 400
8-2
Purpose Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage (high mode) in each copy mode
and the control circuit.
Section Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
(Initial screen) (Input/Selection screen) (Executing screen)
Display items Content
Setting
range
Default
1:AE
AE (
) 1-8 3 (–530V)
2:TEXT
Character 5 (–580V)
3:TEXT/PHOTO
Character/Photo 5 (–580V)
4:PHOTO
Photo 5 (–580V)
5:SUPER PHOTO *
Super photo Disabled
6:TONER SAVE
Toner save 2 (–505V)
NO. Set value Grid High Grid Low
1 480 –480V –350V
2 505 –505V –375V
3 530 –530V –400V
4 555 –555V –425V
5 580 –580V –450V
6 605 –605V –475V
7 630 –630V –500V
8 655 –655V –525V
8-3
Purpose Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage (low mode) in each copy mode
and the control circuit.
Section Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
Sim8-2 MHV(H) COPY
1:AE 3
2:TEXT 5
3:TEXT/PHOTO 5
1/2
Sim8-2 MHV(H) COPY
5:SUPER PHOTO 3
EXEC [ 1- 8] 3
Sim8-2 MHV(H) COPY
5:SUPER PHOTO 3
EXEC [ 1- 8] 3