Specifications

AR-FX8 SIMULATIONS, FAX SOFTWARE SWITCH 6-47
72 7,8 Upper limit of busy tone
OFF detection time
Used to set the upper limit of OFF time when detecting the busy tone signal
frequency. If the busy tone signal is detected over this setup, it is not counted as
one pulse.
0 750ms
0
73 1-8 Not used 0
1
0
1
0
1
1
0
74 1-8 Not used 0
0
0
0
1
1
0
1
75 1-4 Lower limit of call signal
ON time
Used to set the lower limit of ON time for detection of pulses (number of times)
of call signal (CI). When CI signal ON is detected for more than the set time, it is
counted as 1 pulse.
The lower limit of ON time can be set in the range of
150 - 300ms by binary input of N (0 - 15) into "N x 10 + 150ms."
This switch substitutes for the sine wave of CI detection.
0 150ms
0
0
0
5-8 Upper limit of call signal
ON time
Used to set the upper limit of ON time for detection of pulses (number of times)
of call signal (CI). When CI signal ON is detected for less than the set time, it is
counted as 1 pulse.
The upper limit of ON time can be set in the range of
3000 - 4500ms by binary input of N (0 - 15) into "N x 100 + 3000ms."
0 3000ms
0
0
0
76 1-4 Lower limit of call signal
OFF time
Used to set the lower limit of call signal (CI) OFF time for detection of pulses
(number of times). When a CI signal OFF is detected for mote than the set OFF
time, it is judged as 1 pulse. The lower limit of OFF time can be set in the range
of 0 - 150ms by binary input of N (0 - 15) into "N x 100ms."
0 700ms
1
1
1
5,6 Upper limit of call signal
OFF time
Used to set the upper limit of wait time from pulse (number of times) detection
of a call signal (CI) to the next CI signal pulse. When the next CI signal pulse is
not detected within the set range, the number of calls until then is cleared.
0 5sec
0
7,8 Not used 0
0
77 1-4 Call signal OFF non-
detection time
Used to set the time to ignore OFF signal and regard as ON time continuing
after detection of call signal (CI) ON. This is to process PBX call signal (Ring,
Ring) as one call signal.
The set range is 0 - 150ms in the increment of 100ms by binary input.
0 600ms
1
1
0
SW
No.
Bit
No.
Item Switch selection and function USA Initial value Key
operator
Bit No. 7 8
750ms 0 0
650ms 0 1
1000ms 1 0
2850ms 1 1
Bit No. 5 6
5sec 0 0
10sec 0 1
15sec 1 0
20sec 1 1
[06]SIMULATIONS FAXSOFTWARESWITCH.fm 47 ページ 2003年11月12日 水曜日 午前9時45分