Specifications
AR-FX8 SIMULATIONS, FAX SOFTWARE SWITCH 6-43
56 1-7 Not used 0
1
0
0
0
0
0
8 Resend when no
response from the other
party
Used to set whether recall is made by judging no response of the other party as
an error in transmission. No response of the other party is caused when dial is
completed and the other party is a telephone.
0 Recall
57 1-4 Recall interval in busy
state
Differs depending on the destination.
Used to set the recall interval in a communication error or busy state in sending.
The set range is 0 - 15min in the increment of 1min by binary input. When set to
0, the default value of 3min is applied to.
0 3 min Send setup
0
1
1
5-8 Number of times of
recall in communication
error
Used to set the number of times of recall in communication error in sending.
The set range is 0 - 15 times by binary input. When set to 0, the default value of
1 is applied to.
The set range differs depending on the destination.
0 Once Send setup
0
0
1
58 1-4 Number of times of
recall in busy
Used to set the number of times of recall when the other party's line is busy or
the other party does not receive. The set range is 1 - 14 times of 1min by binary
input.
When 0 is selected, it is set to the default (2 times).
The set range differs depending on the destination.
0 2times Send setup
0
1
0
5-8 Recall interval in
communication error
Differs depending on the destination.
Used to set the recall interval in a communication error in sending busy state in
sending.
The set range is 0 - 15min in the increment of 1min by binary input. When set to
0, the default value of 3min is applied to.
0 3 min Send setup
0
1
1
59 1 Not used 1
2 Recall allow in busy Used to set whether recall is made or not when the other party is busy or does
not receive in transmission.
1 Recall Send setup
3 Recall allow in
communication error
Used to set whether recall is made or not when a communication error occurs in
transmission.
1 Recall Send setup
4 Lower limit of dial tone
ON detection time
Used to set the dial tone and the minimum required time for detection of the dial
tone when detecting the dial tone.
0 500ms
5,6 DP dial pulse number
process
Used to set the pulse number when delivering dial pulse. Since the pulse
number differs in different countries, change the setup according to necessity.
0 00
0
7,8 Not used 0
0
60 1-8 Interval from the
completion of
communication to the
next call
Used to set the interval from the completion of communication to the next call.
The set range is 1 - 255sec by binary input. When 0 is selected, it is set to the
default (10sec).
0 10sec
0
0
0
1
0
1
0
SW
No.
Bit
No.
Item Switch selection and function USA Initial value Key
operator
1: Not recall 0: Recall
1: Recall 0: Not recall
1: Recall 0: Not recall
1: 250ms 0: 500ms
Bit No. 5 6
NORMAL (Pulse=DIAL, 10=0) 0 0
EXTEND (Pulse=DIAL+1) 0 1
REVERSE (Pulse=10-DIAL) 1 0
[06]SIMULATIONS ・ FAXSOFTWARESWITCH.fm 43 ページ 2003年11月12日 水曜日 午前9時45分