Service manual

AR-FX7 KEY OPERATOR PROGRAM 8 - 3
2. Power switch
Keep the machine's power switch turned on at all times.
Faxes cannot be received if the power is turned off.
3. Originals
A. Original sizes
NOTE:
Originals that are not a standard size (5-1/2" x 8-1/2", 5-1/2" x 8-1/
2"R, 8-1/2" x 11", 8-1/2" x 11"R, 8-1/2" x 14", 11" x 17") can also be
faxed.
Because the amount of memory is limited, the scannable length of a
long original will vary depending on the resolution setting and the
width of the original. If the memory fills up before the entire original
can be scanned, use a lower resolution setting or shorten the origi-
nal.
There are restrictions on originals that can be scanned using the
RSPF.
*Long originals
Depending on the resolution setting and the width of the original, there
may not be sufficient space in memory to hold a long original. In this
case, refer to the following table and select a lower resolution setting
and/or shorten the original.
B. Scanning area of original
Note that the edges of an original cannot be scanned.
Area that cannot be scanned:
0.2" [5 mm] or less at top edge and 0.2" [5 mm] or less at bottom
edge
Near edge + far edge = 0.24 [6 mm]
C. Automatic reduction of faxed document
If the width of the faxed document is greater than the receiving
machines maximum receivable width, the document will be automati-
cally reduced.
A document can also be faxed without reducing its size. In this case,
the left and right edges will not be transmitted.
4. Own number sending
This function prints the date, time, your programmed senderís name,
your programmed senders fax number, and the page number at the
top center of each page that you fax.
Example of fax page printed out by the receiving machine
1) Date and time: programmed in the custom settings.
2) Senders name: programmed in the key operator programs.
3) Senders fax number: programmed in the key operator programs.
4) Page number: 3-digit number appearing in the format, "page num-
ber/total pages" (only the page number appears if you use manual
transmission or Quick On-Line transmission). If desired, you can
use a key operator program to have the page number omitted.
A. Position of sender's information
You can select whether the sender's information is added outside the
printed fax image or inside the image in the key operator programs.
The initial factory setting is outside the image.
Outside scanned data
None of the transmitted image is cut off; however, the transmitted
image is longer than the scanned image, and thus when both the
sender and the receiver use the same size of paper, the printed fax
may either be reduced or split up and printed on two pages.
Minimum original size Maximum original size
Using the
RSPF
8-1/2" (width) x 5-1/2"
(length)
[210 mm (width) x 148 mm
(length)]
5-1/2" (width) x 8-1/2"
(length)
[148 mm (width) x 210 mm
(length)]
11" (width) x 39.3"*
(length)
[297 mm (width) x 1000
mm (length)]
Long originals can be
loaded.
When the scanning
resolution is Ultra fine,
the maximum length
is 34.6" [880 mm].
Using the
document
glass
11" (width) x 17"
(length)
[297 mm (width) x 420
mm (length)]
11" wide 8-1/2" wide
Standard 39.3" [1000 mm] 39.3" [1000 mm]
Fine 39.3" [1000 mm] 39.3" [1000 mm]
Super fine 39.3" [1000 mm] 39.3" [1000 mm]
Ultra fine 34.6" [880 mm] 39.3" [1000 mm]
ON
Faxed
document
width
Receiving
machines
paper width
Reduced size Ratio
11" x 17" 8-1/2" x 14" 8-1/2" x 14" 1 : 0.70
(Area ratio)
11" x 17" 8-1/2" x 11" 8-1/2" x 11"R 1 : 0.5
(Area ratio)
8-1/2" x 14" 8-1/2" x 11" 8-1/2" x 11"R 1 : 0.64
(Area ratio)
Top edge
Near edge
Bottom edge
Far edge
Area that cannot
be scanned
MAY-11-200X-FRI 03:00 PM SHARP PLANNING DIV. FAX No.0666211221 P.001/001
1)
2)
3)
4)
Direction of transmission
Length of
scanned data
Length of
transmitted data