Service manual

AR-FX7 SOFT SWITCH 7 - 24
S
W
115
1 Scan effective image area
(OC) main scan left edge
image loss
1: 0: +
+0 dots
0
2 Binary
input Bit No.
Setting range
234
0 to ±56 dots
in the interval of 8 dots
0
3 0
4
0
5 Scan effective image area
(OC) main scan right edge
image loss
1: 0: +
+0 dots
0
6 Binary
input Bit No.
Setting range
678
0 to ±56 dots
in the interval of 8 dots
0
7 0
8
0
S
W
116
1 Scan magnification
adjustment OC (main scan)
1: 0: + + 0
2 Binary
input Bit No.
Setting range
2345678
0 to ±12.7%
by increment of 0.1%
0%
0
3 0
4 0
5 0
6 0
7 0
8 0
S
W
117
1 Scan magnification ratio
adjustment OC (sub scan)
1: 0: + + 0
2 Binary
input Bit No.
Setting range
2345678
0 to ±12.7%
by increment of 0.1%
0%
0
3 0
4 0
5 0
6 0
7 0
8 0
S
W
118
1 Scan effective image area
(SPF) sub scan lead edge
image loss
1: 0: +
+0 lines
0
2 Binary
input Bit No.
Setting range
234
0 to ±56 lines
in the interval of 8 lines
0
3 0
4
0
5 Sub scan rear edge image
loss in scan effective image
area (SPF)
1: 0: +
+0 lines
0 Since the rear edge
of the SPF cannot be
specified with
coordinates, it is
pulled after scanning,
Since the set value is
not a coordinate
value, its unit differs
from that of the other
set values. The value
cannot be increased
over the coordinates
specified in scanning.
6 Binary
input Bit No.
Setting range
678
0 to ±14 lines
in the interval of 2 lines
0
7
0
8
0
S
W
119
1 Scan effective image area
(SPF) main scan left edge
image loss
1: 0: +
+0 dots
0
2 Binary
input Bit No.
Setting range
234
0 to ±56 dots
in the interval of 8 dots
0
3 0
4
0
5 Scan effective image area
(SPF) main scan right edge
image loss
1: 0: +
+0 dots
0
6 Binary
input Bit No.
Setting range
678
0 to ±56 dots
in the interval of 8 dots
0
7 0
8
0
SW
No.
Data
No.
Items SW selection and functions Default value Remarks