Service manual
AR-FX7 SOFT SWITCH 7 - 23
S
W
108
1 Inhibited to use 0
2 0
3 0
4 0
5 0
6 1
7 0
8 1
S
W
109
1 Print lead edge adjustment
(Left edge adjustment)
1: – 0: + + 0
2 Binary
input Bit No.
Setting range
234
0 to ±112 dots
in the interval of 16 dots
48 dots
0
3 1
4
1
5 Print lead edge adjustment
(Lead edge adjustment)
1: – 0: + + 0
6 Binary
input Bit No.
Setting range
678
0 to ±112 lines
in the interval of 16 lines
48 lines
0
7 1
8
1
S
W
110
1 Print lead edge adjustment
(Rear edge adjustment)
1: – 0: + + 0
2 Binary
input Bit No.
Setting range
234
0 to ±112 lines
in the interval of 16 lines
48 lines
0
3 1
4
1
5 Print lead edge adjustment
(left edge position) rear
1: – 0: + + 0
6 Binary
input Bit No.
Setting range
678
0 to ±112 dots
in the interval of 16 dots
48 dots
0
7 1
8
1
S
W
111
1 Print lead edge adjustment
(lead edge position) rear
1: – 0: + + 0
2 Binary
input Bit No.
Setting range
234
0 to ±112 lines
in the interval of 16 lines
48 lines
0
3 1
4
1
5 Print lead edge adjustment
(rear edge position) rear
1: – 0: + + 0
6 Binary
input Bit No.
Setting range
678
0 to ±112 lines
in the interval of 16 lines
48 lines
0
7 1
8
1
S
W
112
1 Print magnification ratio
adjustment (main scan)
1: – 0: + + 0
2 Binary
input Bit No.
Setting range
2345678
0 to ±12.7%
by increment of 0.1%
0%
0
3 0
4 0
5 0
6 0
7 0
8 0
S
W
113
1 Print magnification radio
adjustment (sub scan)
1: – 0: + + 0
2 Binary
input Bit No.
Setting range
2345678
0 to ±12.7%
by increment of 0.1%
0%
0
3 0
4 0
5 0
6 0
7 0
8 0
S
W
114
1 Scan effective image area
(OC) sub scan lead edge
image loss
1: – 0: +
+0 lines
0
2 Binary
input Bit No.
Setting range
234
0 to ±56 lines
in the interval of 8 lines
0
3 0
4
0
5 Sub scan rear edge image
loss in scan effective image
area (OC)
1: – 0: +
+0 lines
0
6 Binary
input Bit No.
Setting range
678
0 to ±56 lines
in the interval of 8 lines
0
7 0
8
0
SW
No.
Data
No.
Items SW selection and functions Default value Remarks