Service manual
AR-FX7 SOFT SWITCH 7 - 20
S
W
87
1 CI signal OFF detectable
time
Binary
input Bit No.
Setting range
1234567
0 to 1270ms
by increment of 10ms
1200ms
1
2 1
3 1
4 1
5 0
6 0
7 0
8 Inhibited to use 0
S
W
88
1 Inhibited to use 0
2 1
3 0
4 0
5 0
6 1
7 1
8 0
S
W
89
1 Inhibited to use 1
2 1
3 0
4 1
5 1
6 0
7 0
8 0
S
W
90
1 Inhibited to use 0
2 1
3 1
4 1
5 1
6 1
7 1
8 1
S
W
91
1 Inhibited to use 0
2 1
3 0
4 0
5 0
6 0
7 0
8 0
S
W
92
1 Inhibited to use 0
2 1
3 0
4 1
5 1
6 0
7 0
8 0
S
W
93
1 Inhibited to use 1
2 0
3 0
4 0
5 0
6 0
7 0
8 0
SW
No.
Data
No.
Items SW selection and functions Default value Remarks