Service manual

AR-FX7 SOFT SWITCH 7 - 8
S
W
31
1 Inhibited to use 0
2 0
3 Time specification print
(minute) on the
communication record table
Binary
input Bit No.
Setting range
345678
00 to 59 min
0 min
0 When the value is
outside the setting
range, the initial
value is set.
4 0
5 0
6 0
7 0
8 0
S
W
32
1 Default telephone book
setup
Bit No. 1 2
Basic screen
0
Basic screen 0 0
2 Destination list
(50-character kana
syllabary
01
0
Destination list
(user)
10
3 Next address key input in
broadcast
1: Yes 0: No
No 0
4 One-touch dial display
number switch
Bit No. 4 5
8 items
0
6 items 0 0
58 items01
1
12 items 1 0
6 Shift of the power OFF state
in shut off
1: Allowed 0: Inhibited
Allowed 1
7 Time indication format 1: AM/PM 0: 24H AM/PM 1
8 Priority in the day of week 1: Yes 0: No No 0
S
W
33
1 Inhibited to use 0
2 Report output on less than
A4 (LTR)
1: Reduction as A4 (LTR)
images
0: Reduction by the record
volume
Reduction by the
record volume
0
3 Inhibited to use 0
4 Contents of send document
are printed in memory send
error
Bit No. 4 5
When
transmission is
failed
1
Not print 0 0
5 Print all 0 1
0
When transmission
is failed
10
6 Transmission document
content print in F code
transmission
1: Not print 0: Print
Not print 1
SW33-4 5 must be
set to output.
7 Function to attach images
to the report table of
memory confidential send
1: Yes 0: No
No 0
8 Total communication time
and total number of pages
print on communication
record table
1: Yes 0: No
Yes 1
SW
No.
Data
No.
Items SW selection and functions Default value Remarks