Service manual

AR-FX7 SOFT SWITCH 7 - 6
S
W
20
1 Inhibited to use 0
2 0
3 0
4 0
5 SIM DTMF sound speaker
selection window
1: Yes 0: No
No 0
6 Flash send wait time Bit No. 6 7
0sec
0
0 fixed
0sec 0 0
0.5sec 0 1
7 1sec 1 0
0
2sec 1 1
8 Receivable memory
capacity
1: 64Kbyte 0: 128Kbyte
128Kbyte 0
S
W
21
1 Dial tone detection 1: Yes 0: No No 0
2 Busy tone detection 1: Yes 0: No Yes 1
3 Dial tone monitoring time 1: 10sec 0: 5sec 5sec 0
4 CED detection time 1: 500ms 0: 1000ms 1000ms 0
5 Inhibited to use 0
6 0
7 0
8 0
S
W
22
1 Waiting time for dial start Bit No. 1 2
3.5sec
03.5sec 0 0
4sec 0 1
2 5sec 1 0
0
6sec 1 1
3 CNG send start time Bit No. 3 4
0.5sec
0
0.5sec 0 0
41.0sec01
0
1.5sec 1 0
5 Tone/pulse default setup Bit No. 5 6
TONE
1
10PPS 0 0
6 20PPS 0 1
0
TONE 1 0
7 DPMUTE control 1: ON 0: OFF OFF 0
8 DP dial pulse number
process
1: 10-N 0: Normal (N)
Normal (N) 0
S
W
23
1 Inhibited to use 0
2 Monitoring polarity
reversion during send
image
1: Yes 0: No
No 0
Fixed to NONE.
3 Monitoring polarity
reversion during
communication
1: Yes 0: No
No 0
Fixed to NONE.
4 Setting of time before dial
(10PPS)
Binary
input Bit No.
Setting range
45678
0 (50ms) to 31 (360ms)
X (ms) = (N × 10) + 50
60ms
0
5 0
6 0
7 0
8 1
S
W
24
1 Inhibited to use 0
2 0
3 0
4 0
5 Waiting time for OFF HOOK Binary
input Bit No.
Setting range
5678
0 (50ms) to 15 (200ms)
X (ms) = (N x 10) + 50
100ms
0
6 1
7 0
8 1
SW
No.
Data
No.
Items SW selection and functions Default value Remarks