Service manual

AR-FX7 SOFT SWITCH 7 - 5
S
W
14
1 Recall number in case of a
transmission error
Binary
input Bit No.
Setting range
1234
0 to 1 times
1 times
0 When the value is
outside the setting
range, the initial
value is set.
2 0
3 0
4 1
5 Recall interval in
communication error
Binary
input Bit No.
Setting range
5678
0 to 15 min
0: Recall immediately after
cutting the line
1 min
0 When the value is
outside the setting
range, the initial
value is set.
6 0
7 0
8
1
S
W
15
1 Inhibited to use 0
2 0
3 0
4 Signal send level Binary
input Bit No.
Setting range
45678
0 (0dBm) to 26 (26dBm)
11dBm
0
5 1
6 0
7 1
8 1
S
W
16
1 Modem speed (V.33 mode
or less)
Bit No. 1 2 3 4
V.17 14.4kbps
1V.27 2400bps 0 0 0 0
V.29 9600bps 0 0 0 1
2 V.27 4800bps 0 0 1 0
0V.29 7200bps 0 0 1 1
V.33 14.4kbps 0 1 0 0
3 V.33 12.0kbps 0 1 1 0
0V.17 9600bps 1 0 0 1
V.17 12.0kbps 1 0 1 0
4 V.17 7200bps 1 0 1 1
0
V.17 14.4kbps Other than the
above
5 Modem speed in reception
fixed
Bit No. 5 6
No fixing
0No fixing 0 0
V.29-9600BPS 0 1
6 V.27ter-4800BPS 1 0
0
V.17-14400BPS 1 1
7 EOL detection timer 1: 25sec 0: 13sec 13sec 0
8 RTN EOL send times 1: 6 times 0: 12 times 6 times 1
S
W
17
1 Inhibited to use 0
2 MH fixed (except for SG3) 1: Yes 0: None (depending on the
remote machine)
No 0
3 ECM MMR mode (except
for SG3)
1: Yes 0: No
Yes 1
4 ECM JBIG mode (except for
SG3)
1: Yes 0: No
Yes 1
5 Inhibited to use 0
6 MH fixed (SG3) 1: Yes 0: None (depending on the
remote machine)
No 0
7 ECM MMR mode (SG3) 1: Yes 0: No Yes 1
8 ECM JBIG mode (SG3) 1: Yes 0: No Yes 1
S
W
18
1 Setup of number of times of
call rings
Binary
input Bit No.
Setting range
1234
0 to 9 times
2 times
0
2 0
3 1
4 0
5 Inhibited to use 0
6 0
7 0
8 0
S
W
19
1 Minimum pause time
(10PPS) setup
Binary
input Bit No.
Setting range
1234
0 (525ms) to 15 (900ms)
X (ms) = (N × 25) + 525
750ms
1
2 0
3 0
4 1
5 Inhibited to use 0
6 0
7 0
8 0
SW
No.
Data
No.
Items SW selection and functions Default value Remarks