Service manual
AR-FX7 SOFT SWITCH 7 - 4
S
W
9
1 Proxy reception 1: Yes 0: No Yes 1
2 Transfer function 1: Allowed 0: Inhibited Allowed 1
3 Relay broadcast function 1: Allowed 0: Inhibited Allowed 1
4 Inhibited to use 0
5 0
6 Cover function default setup 1: Yes 0: No No 0
7 Specified number receive
reject
1: Reject 0: Not reject
Not reject 0
8 Specified number receive
reject I manual receive
1: Reject 0: Not reject
Reject 1
S
W
10
1 F-code relay broadcast
function
1: Inhibited 0: Allowed
Allowed 0
2 F-code confidential
reception
1: Inhibited 0: Allowed
Allowed 0
3 Yes/No of SUB capacity in
reception
1: No 0: Yes
Yes 0
4 Yes/No of SEP capacity in
reception
1: Inhibited 0: Allowed
Allowed 0
5 Yes/No of reception PWD
capacity
1: Inhibited 0: Allowed
Allowed 0
6 Yes/No of SID capacity in
reception
1: Inhibited 0: Allowed
Allowed 0
7 Judgment of the system
number of bulletin board
transmission
1: Allowed 0: Inhibited
Inhibited 0
8 Send request protection 1: Not protected 0: Protected Protected 0
S
W
11
1 Department management 1: Allowed 0: Inhibited Inhibited 0
2 Inhibited to use 0
3 Sender’s telephone number
registration
1: No 0: Yes
Yes 0
4 Yes/No of manual send
selection menu display
1: Displayed 0: Not displayed
Displayed 1
5 Distinctive ringing Bit No. 5 6 7 8
OFF
0
OFF 0 0 0 0
6 Standard/ON 0 0 0 1
0
Pattern1 1000
7Pattern20100
0
Pattern3 1100
8Pattern40010
0
Pattern5 1010
S
W
12
1 Direct send recall Allow/
Inhibit
1: Allowed 0: Inhibited
Allowed 1
2 Inhibited to use 0
3 1
4 0
5 0
6 1
7 0
8 Remote selection models 1: Both call-in and call-out 0: Call-in only Call-in only 0
S
W
13
1 Recall times in busy Binary
input Bit No.
Setting range
1234
0 to 14 times
2 times
0 When the value is
outside the setting
range, the initial
value is set.
2 0
3 1
4 0
5 Recall interval in busy Binary
input Bit No.
Setting range
5678
1 to 15 min
3 min
0 When the value is
outside the setting
range, the initial
value is set.
6 0
7 1
8 1
SW
No.
Data
No.
Items SW selection and functions Default value Remarks