Specifications
AR-FX5 MACHINE OPERATION 7-6
C. Communication report sub code
*1: Does not occur in this machine.
Report code 2 Content of communication interruption Send/Receive
01 Send length over Send
02 EOL time up Receive
03 Carrier detection time up Receive
04 Not used -
05 Time up in phase C (8 min) Send
06 Memory image decode error Receive
07 Memory image decode error Send
08 Time up between frames in phase C (Report code is 0 or 16.) Send/Receive
09 Not used -
10 Not used -
11 Polarity reversion detection Receive
12 Invalid command reception Receive
13 Time up (1-minute timer/6-second time) Receive
14 PUT error Receive
15 In V.34 mode, time up is generated when shifting from Primary to Control. Receive
16 In V.34 mode, time up is generated when shifting from Control to Primary. Receive
17 Not used -
18 Not used -
19 Not used -
20 Polarity reversion detection Send
21 Invalid command reception Send
22 Fallback retry number over Send
23 Command retry number resend over Send
24 Time up (T5 timer) Send
25 Time up (T5 timer) in V.34 mode Send
26 In V.34 mode, time up is generated when shifting from Primary to Control. Send
27 In V.34 mode, time up is generated when shifting from Control to Primary. Send
28 Modem chip response NG *1 Send/Receive
29 Not used -
30 A communication error is generated between MFP controller and model controller. (Report code is 0 or 16.)
31 DC current not detected (busy) Send
32 Dial tone not detected (busy) Send
33 Busy tone detection (busy) Send
34 T0 time up (Remote machine not responding) Send
35 T1 time up (Remote machine not responding) Send
36 In dialing, polarity reversion detection (Remote machine not responding) Send
37 Calling is not made (busy)<Collision detected> Send