Specifications
AR-FX5 SIMULATIONS, FAX SOFTWARE SWITCH 6-37
41 1,2 Report output
(transmission)
Used to set the communication report table output after transmission
(except for sequential broadcast, sequential polling, relay broadcast).
1 Only when
transmission
failed
Initial setup
0
3,4 Not used 0
0
5,6 Report output
(sequential broadcast,
sequential polling, relay
broadcast)
Used to set the communication report table output after transmission
(sequential broadcast, sequential polling, relay broadcast).
0 All print Initial setup
1
7,8 Report output
(reception)
Used to set the communication report table output in reception
(except for confidential reception).
0Print
inhibited
Initial setup
0
42 1-3 Not used 0
0
0
4 Win FAST function Used to set the management function by FAX communication procedures through
the telephone line.
0NO
5-7 Not used 0
0
0
8 V.34 mode function in
manual communication
Used to set Enable/Disable of V.34 mode function in manual communication.
When, however, SW43-1 is set to "1:disable," V.34 mode is disabled though this
switch is set to "0:enable."
0Enable
43 1 V.34 mode function Used to set Enable/Disable of V.34 mode function in the machine when sending/
receiving.
0Enable
2 Not used 0
3-6 V.34Symbol Rate Mask
(when receiving)
Used to set Symbol Rate in reception of V.34 mode.
When set to other than the below, it is set as the default (0101).
0 3429
1
0
1
7,8 Not used 0
0
SW
No.
Bit
No.
Item Switch selection and function Initial value
Key
operator
Bit No. 1 2
Print inhibited 0 0
All print 0 1
Only when transmission is failed 1 0
Only when transmission is failed 1 1
Bit No. 5 6
Print inhibited 0 0
All print 0 1
Only address to which transmission is failed 1 0
All print 1 1
Bit No. 7 8
Print inhibited 0 0
All print 0 1
Only in case of an error 1 0
Print inhibited 1 1
1: YES 0: NO
1: V.34 mode function disable 0: V.34 mode function enable
1: V.34 mode function disable 0: V.34 mode function enable
Bit No. 3456
2400 0 0 0 0
2400 0 0 0 1
2800/2400 0 0 1 0
3000/2800/2400 0 0 1 1
3200/3000/2800/2400 0 1 0 0
3429/3200/3000/2800/2400 0 1 0 1