Specifications
AR-FX5 SIMULATIONS, FAX SOFTWARE SWITCH 6-27
7 1 Telephone/FAX
automatic selection
This setting is enabled only when external telephone connection or handset
connection is set to YES.
0 NO Initial setup
2 Auto/Manual default
setup
Used to select automatic reception or manual reception. (Do not set to manual
reception when handset or external telephone is not connected. However, setting
is possible and reception with on-hook key is possible.) In the manual reception
mode, when the machine is in the nighttime FAX mode, the machine is booted but
reception ringing is not made.
0 Auto
reception
User setup
3 Not used 0
4 Max. length of reception Used to set whether long document transmitted from the other party is received
without limitation or reception is terminated as "Reception length over" when
received document length reaches 1.5m. The max. length for transmission is
monitored by MFP controller (Machine side).
0 Terminate
5 Remaining memory
capacity for reception
Used to set whether reception receive is made until remaining memory capacity
reaches 64KB or less or 128KB or less.
0 128KB or
less
6 Memory over during
reception
Used to set whether received data are outputted or disregarded without outputting
in case of memory over during reception.
0 Output
7,8 Not used 0
0
8 1,2 Image capacity in send
request
(reflected on DTC)
Used to set image capacity of the machine when polling. It is reflected on DTC,
and is unrelated to SW5-2-5 (Image capacity during reception).
0 Ultra fine
0
3 Error page output
selection in FAX
reception error
Used to set whether error page is outputted or disposed without outputting in case
of a communication error during FAX reception.When, however, an error occurs
during F code relay instruction reception or F code confidential reception, the error
page is not outputted regardless of this SW setup.
0 Output
4 Quick online/memory
transmission selection
Used to select quick online transmission mode or memory transmission mode. 0 Quick online
transmission
Send setup
5-8 Number of pages of dial
ringing in quick online
transmission
Used to set the number of pages of scanning at the dial ringing timing in quick
online transmission. Can be set in the range of 0 - 15 pages by binary input.
0 1 page
0
0
1
9 1-4 Number of ringing by
external telephone
pseudo-ringing
(Ring back tone is sent
in synchronization.)
Used to set the number of pseudo-ringing (machine is also ringing) of external
telephone and ring back tones to the line in automatic selection of TEL/FAX.
Can be set in the range of 0 - 15 times. When set to 0, however, ringing is made 99
times.
0 6 times Initial setup
1
1
0
5-8 Number of ring back
tone preceding
transmission
(number of times until
ringing by external
pseudo-ringing is
started)
Used to set the number of times of RBT transmission to the other party machine
until external telephone is called after ringing in automatic selection of TEL/FAX.
Can be set in the range of 0 - 15 times. Effective only in Japan.
03 times
0
0
0
SW
No.
Bit
No.
Item Switch selection and function Initial value
Key
operator
1: TEL/FAX auto switch YES 0: TEL/FAX auto switch NO
1: Manual reception 0: Auto reception
1: Receive without limitation 0: terminate reception at 1.5m or more
(Communication error)
1: Receive until remaining memory is
64KB or less.
0: Ringing until remaining memory is
128KB or less.
1: Received data are not outputted. 0: Received data are outputted.
Bit No. 1 2
Standard 1 1
Fine 1 0
Super fine 0 1
Ultra fine 0 0
1: Error page is not outputted. 0: Error page is outputted.
1: Memory transmission 0: Quick online transmission