Service manual
AR-235/275 SIMULATION - 30
Operation/procedure (Pattern 2)
Select the mode with the 10-key and press the [OK] key.
Enter the adjustment value with the 10-key and press the [OK] key, and
the entered value is registered.
Pressing the [BACK] key returns to the mode selection.
If SIM 26-6 (Destination setup) and SIM46-19 (Auto exposure mode)
are changed, this setup is also changed to the default value accord-
ingly.
Operation/procedure (Pattern 5)
Select the mode with the arrow keys, enter the adjustment value with
the 10-key, and press the [OK] key.
When the [START] key is pressed, a print is made and the display
returns to the mode selection menu.
Setup of various copy conditions: Similar to the normal copy mode.
Use of [SPECIAL FUNCTION] key, [JOB STATUS] key, and [INTER-
RUPT] key is inhibited.
Operation/procedure (Pattern 5)
Select the mode with the arrow keys, enter the adjustment value with
the 10-key, and press the [OK] key.
When the [START] key is pressed, a print is made and the display
returns to the mode selection menu.
Input the offset for the copy adjustment.
Setup of various copy conditions: Similar to the normal copy mode.
Use of [SPECIAL FUNCTION] key, [JOB STATUS] key, and [INTER-
RUPT] key is inhibited.
Open the OC cover, and put the lead edge/sub scan automatic adjust-
ment chart on the OC. (Keep the OC cover open.)
Place the chart correctly on the OC reference position. (If not, a correct
adjustment cannot be made.)
If the adjustment is normally completed, the adjusted value is dis-
played and written into the EEPROM. In case of an abnormality, "ERR"
is displayed and the value is not written into the EEPROM.
If no adjustment is made because of an abnormality, "---" is displayed.
(Initial screen) (Input screen)
Display items Content Setting range Default
1:SPF EXPOSURE
SPF 1-99 50
2:RSPF EXPOSURE
RSPF
46-30
Purpose
Setting
Function
(Purpose)
Used to set the AE limit.
(Initial screen) (Input screen)
Display items Setting range Default
1:AE
0-31 0
2:AE(TS)
48
48-1
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy mode magnification ratio (main
scanning direction, sub scanning direction).
Section
Image processing
Item
Picture quality
(Initial screen) (Input screen) (Executing screen)
Display items Content
Setting
range
Default
1:F-R(AUTO)
Main scanning magnification
ratio adjustment (auto)
––
2:F-R
Main scanning magnification
ratio adjustment
1-99 50
3:SCAN
Sub scanning magnification
ratio adjustment
60
4:SPF(SIDE1)
SPF surface sub scan
magnification ratio
50
5:SPF(SIDE2)
SPF back surface sub scan
magnification ratio
6:DUPLEX
DUPLEX sub scanning
magnification ratio adjustment
Sim46-20 SPF EXP.
1:SPF EXPOSURE 50
2:RSPF EXPOSURE 50
1
Sim46-20 SPF EXP.
1:SPF EXPOSURE 50
[ 1- 99] 50
Sim46-30 AE LIMITTE
1:AE 0
2:AE(TS) 0
1
Sim46-30 AE LIMITTE
1:AE 0
[ 0- 31] 0
Sim48-1 COPY MAG.
1:F-R(AUTO) 50
2:F-R 50
3:SCAN 50
1/2 50
48-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner mode magnification ratio
(main/sub scanning direction).
Section
Image processing
Item
Picture quality
(Initial screen) (Input screen) (Executing screen)
Display items Content
Setting
range
Default
1:F-R
Main scanning magnification
ratio adjustment
1-99 50
2:SCAN
Sub scanning magnification
ratio adjustment
3:SPF(SIDE1)
SPF surface sub scan
magnification ratio
4:SPF(SIDE2)
SPF back surface sub scan
magnification ratio
48-3
Purpose
Adjustment
Function
(Purpose)
Used to adjust the lead edge/sub scan magnification
ratio automatically.
Item
Operation
(Initial screen) (Execution screen)
(Normal end screen) (Abnormal end screen)
Sim48-2 SCANNER MAG
1:F-R 50
2:SCAN 50
3:SPF(SIDE1) 50
1/2 50
Sim48-3 READ AUTO
PRESS OK KEY EXEC
Sim48-3 READ AUTO
EXEC
Sim48-3 READ AUTO
RRC-A [ 32]
OC Center [ 53]
MirSpeed [ 58]
PRESS OK KEY EXEC
Sim48-3 READ AUTO
RRC-A [ ERR]
OC Center [ ERR]
MirSpeed [ ---]
PRESS OK KEY EXEC