Service manual
AR-235/275 SIMULATION - 25
Operation/procedure
The AD conversion value of manual feed width detection is displayed.
Operation/procedure
The operation status of the sensors and detectors in the original size
detection section are displayed. The active sensors and detectors are
highlighted.
For AB series, PD1 - 5 is displayed, for inch series, PD1 - 4.
Operation/procedure
Place an A3 (or WLT) document on the document table, and press
[OK] key with the OC cover open.
The adjustment is performed and the result is displayed.
The value in [ ] shows the threshold value.
For AB series, 1 - 5 is displayed, for inch series, 1 - 4.
During execution, [EXEC] is highlighted.
Operation/procedure
The detection output level of each sensor is displayed in real time.
The value in [ ] shows the threshold value of 20 degree detection
adjustment.
For AB series, 1 - 5 is displayed, for inch series, PD1 - 4.
Operation/procedure
Set the OC cover at 20 degrees detection and press the [OK] key.
The detection output level of each sensor is displayed in real time.
The value in [ ] shows the threshold value of 20 degree detection
adjustment.
For AB series, 1 - 5 is displayed, for inch series, 1 - 4.
During execution, [EXEC] is highlighted.
(Adjustment result screen)
Adjustmen state is displayed.
Paper width detection (+) adjustment
value
Paper width detection (–) adjustment
value
Intermediate position L YES : LON
Intermediate position L NO : LOFF
Intermediate position S YES : SON
Intermediate position S NO : SOFF
40-3
Purpose
Adjustment
Function
(Purpose)
The AD conversion value of manual feed width
detection is displayed.
Section
Paper feed
Item
Operation
41
41-1
Purpose
Operation test/check
Function
(Purpose)
Used to check the document size detection photo
sensor.
Section
Others
Item
Operation
OCSW Original cover state
Open: Highlighted
display
Close: Normal display
PD1 to 5 Original sensor status
Without original:
Normal display
With original:
Highlighted display
41-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the detection level of the document size
photo sensor.
Section
Others
Item
Operation
Sim40-2 MB SENSOR
PAPER + 60
PAPER - 40
COMPLETE
LON SON
Sim40-3 MB SENSOR
AD CONVERT VALUE
[123]
Sim41-1 PD SENSOR
OCSW PD1 PD2
PD3 PD4 PD5
(Initial screen)
(Executing screen)
OCSW Original cover state
Open: Highlighted display
Close: Normal display
1 to 5 PD sensor detection
level
41-3
Purpose
Operation test/check
Function
(Purpose)
Used to check the light reception level and the
detection level of the original size detection photo
sensor.
Section
Others
Item
Operation
OCSW Original cover state
Open: Highlighted display
Close: Normal display
1 to 5 PD sensor detection
level
41-4
Purpose
Adjustment
Function
(Purpose)
Used to adjust the detection level of OC 20 degrees.
Section
Others
Item
Operation
(Initial screen)
(Executing screen)
OCSW Original cover state
Open: Highlighted
display
Close: Normal display
1 to 5 PD sensor
detection level
Sim41-2 PD SENSOR
PRESS OK KEY EXEC
Sim41-4 20˚ SENSOR
PRESS OK KEY EXEC